14 | Lap Trigger

14.2 Counting outing/laps/fragments

90 / 112
Functionality
– Power ON: system + measurement is initialized but not yet started
– Global start condition fulfilled: recording starts
– Reception of valid lap trigger: recording of lap completed, new lap starts
– Power OFF or Global start condition not fulfilled: recording of lap completed, system
shutdown
The system is counting:
Outing:
– The outing counter is incremented with each power cycle when at least one valid lap
(not by forced lap trigger) was recorded
Lap:
– Leaving the pits to lap trigger
– Lap trigger to lap trigger
– Enforced lap trigger (see Distance based forced trigger [} 92])
Fragment:
– Test bench operation
– Power cycle on track or box (e.g. engine stalled)
– File fragmentation size [MB], time [sec]
Channels for display
To display counters use the following channels:
Channel
Laptrigger_outcnt_dls
Laptrigger_lapctr_dls
Fractr
Counting in WinDarab
To automatically name recorded files use filename templates in WinDarab dialog:
Filename template
[outing]
[lap]
[fragment]
Data Logger C 70 Manual
Function
Outing counter
Lap counter
Fragment counter
Function
Value of outing counter
Value of lap counter
Value of fragment counter