11 | Online Measurement
11.4.3 Assigning channels to the group adjustment
11.4.4 Triggering the group adjustment
76 / 108
NOTICE
Working with automatically created measurement sheets is ex-
plained in chapter 'Setting up an online measurement'.
4.
Click 'Finish' when done.
5.
Enter channel name and description.
6.
Click 'OK' when done.
1.
Double-click on the created channel (e.g. 'grp_adj_channel') in the Project Tree.
2.
In the Main Area, an overview of the available adjustment channels opens.
3.
To add measurement channel(s) to the group adjustment event, check the 'Calibrate'
box of the desired channel(s).
The selected measurement channels are added to the group adjustment event.
1.
Connect the input pin to GND using a push-button.
2.
Make sure the pullup-resistor is enabled, if you selected 'active low' trigger polarity.
3.
Double-click on the input channel 'grp_adj_channel' of the group adjustment.
4.
Download the configuration on the C 60. To connect the C 60 to RaceCon, see
chapter 'Connecting the Unit to RaceCon'.
5.
Open a measurement sheet by clicking on the desired measurement sheet in the Pro-
ject Tree.
6.
Drag the 'grp_adj_channel' and the 'input_grp_adj_channel' to the online measure-
ment sheet.
7.
Press and release the push-button.
8.
The measurement labels indicate the state of the input pin and the state of the ad-
justment.
Data Logger C 60
Signal is active high
or active low
Define minimum active
time to detect activation
Define minimum time
between two activations
Enter name to
automatically create a new
measurement sheet