Bosch C60 Manual page 68

Hide thumbs Also See for C60:
Table of Contents

Advertisement

10 | Analog and Frequency Inputs
10.11.1 Configuring a PWM output
68 / 108
Duty cycle 20%
(switch closed)
U
out
Output frequency
Duty cycle 80%
U
out
Output frequency
1.
Click on 'Measurement Sources' in the Toolbox.
2.
Drag the 'PWM Out' computed source from the Toolbox and drop it on the desired
'PWM_OUT' channel in the C 60 Project Tree.
3.
A 'PWM Out Wizard' opens.
NOTICE
Working with automatically created measurement sheets is ex-
plained in chapter 'Setting up an online measurement'.
NOTICE
Choosing a filtered channel as an input for 'PWM_OUT' will cause
delayed reaction due to the delay introduced by the digital filter.
Use unfiltered values for this purpose.
Data Logger C 60
Time
Time
Choose input
channel
Choose output frequency
Define characteristic curve
Enter name to
automatically create a new
measurement sheet
Bosch Motorsport