11.2.2 Using the measurement sheets
11.3 Online calibration of measurement channels
Bosch Motorsport
The automatically created sheet is inserted in the Project Tree under 'Measurement Con-
tainer' and 'Device Channels'. If the C 60 is connected to RaceCon, live values of the chan-
nels are shown.
The Button "Zero Point Adjustment" is active when the C 60 is online. This function zeros
only when this functionality is activated in the settings of this channel. (see chapter 'En-
able online offset calibration for measurement channel [} 74]')
1.
When RaceCon is online, press the 'F11' key to switch from 'Design Mode' into 'Race
Mode'.
2.
The measurement sheet is extended to full screen.
3.
The button for offset calibration is active.
4.
Switch between different sheets using the tabs at the bottom of the page or the key-
board shortcuts associated with the sheets.
5.
Press the 'Esc' key to return to 'Design Mode'.
– Analog sensors drift with age, temperature, etc.
– Manual calibration is necessary
– Solution: online offset calibration
– Example: acceleration sensor
Data Logger C 60
Online Measurement | 11
73 / 108