The Preparation Of The Measurement Point - Adash 4900 Vibrio Ex User Manual

Table of Contents

Advertisement

ADASH Ltd.
Adash 4900 – Vibrio M
The measurement points need to be prepared for the measurements. The best is to place measuring
pads on a machine (see the chapter Preparation of Measuring Location).

The preparation of the measurement point

On the measurement point we make a measurement. To obtain a quality measurement, the points for
measurements must be prepared in advance. For regular measurements the sensor must be always
fixed in the same way at the same point. For diagnostics of bearings it is necessary to fix the sensor
with a magnetic base. Do not push the sensor only by hand - high frequencies cannot be measured in
this way.
The magnetic base is firmly screwed to the sensor and then it is magnetically fixed to the metal
surface of the machine. Hence the sensor is fixed and a measurement is possible. Quality of fixation
markedly influences the result of your measurement. If the sensor swings or jumps about etc., your
measurement is pointless. A layer of paint is also a big obstacle for higher frequencies. The magnetic
base has ground surface and the same surface quality must be created on the machine. In practice, it
is not possible. A flat surface 3x3 cm in size can be ground only in a workshop. Anyway, quality of the
bearing's housing steel is not high and such a surface can quickly succumb to corrosion. Then it
becomes unusable.
Solution to this problem is to use measurement pads. These are the cylinders with the diameter
approx. 26 mm and height 10 mm with a ground surface, made of a magnetic stainless steel. They are
fixed to chosen points with special glue, which ensures a perfect transmission of the high frequency
vibrations. The pad is covered with a plastic cover, which is removed only for the measurement.
Another advantage of the cover is that when the machine is painted, your measurement point is
preserved. The paint would devalue the pad. It is sufficient to coarsely grind the machine's surface and
degrease it before the pad is glued. Durability of the pads in time is unlimited. In practice, it is always
until a forcible removal.
You will need mainly the following aids: angle grinder, set of files, sand paper, degreaser (ethanol,
solvent), measurement pads and glue.
Prepare the surface in the following way:
- remove the paint, corrosion or unevenness from the surface by grinding,
- degrease the surface.
The pad is being fixed on measurement point with the glue. We usually use the METAL TECH SG
cement, also other glues with similar properties may be used.
The METAL TECH SG cement is a 2-component epoxy cement with properties best suited for this
task. The two components, after mechanical mixing, chemically react and after drying they form a hard
material resistant to pressure, temperature and humidity.
In the case of the simple pad the procedure is as follows: cut-off a disc approx.3 mm thick from the
cement with a sharp knife. Wet your fingers and work the disc into a homogenous lump. Roll a cylinder
with the diameter approx. 2-3 mm from this lump and put it on the side, which is not roughened.
11
Further technical and contact information can be found at www.adash.com