Vibration Diagnostics - Basic Information; Introduction; Basic Rules - Adash 4900 Vibrio Ex User Manual

Table of Contents

Advertisement

ADASH Ltd.
Adash 4900 – Vibrio M

Vibration Diagnostics - Basic Information

Introduction

What is it the vibration diagnostics? This chapter explains the basic steps and you will be able to begin
practical measurements. More information you can find in the literature.
When we are talking about the vibration diagnostics, we mean regular measurements (usually
every 2-4 weeks), whose objectives primarily are:
1. Finding of change of vibration level, it means change of machine operational condition.
2. Determining reason of this change.
3. Recommending maintenance (repair, adjustment, lubrication etc.).
4. Checking of maintenance success (including revision of dismantled part to confirm the
analysis).
The machine vibration diagnostics solves two basic tasks:
1. Diagnostics of machine mechanical failure (imbalance, misalignment, mechanical
looseness etc.).
2. Diagnostics of rolling bearing condition.

Basic Rules

1. If the measured value of vibration increases in time, it is a change indicator - worsening of
the machine condition.
2. If the measured values do not change, the machine works in stable operation condition.
This doesn't necessarily mean good condition. For example if a bearing was installed incorrectly, then
there will be high signal value immediately. This value will remain stable for some time (the bearing will
be able to withstand it), but then there will be a fast increase and destruction of the bearing. This short
bearing life can take hours, days, weeks or even months.
3. Reliability of the diagnostics will never be 100%.
There will always be defects, which develop in time shorter than regular measurements. The defects
caused by material fatigue can develop in several seconds only (cracks, breaks). The proof of the
diagnostic performance is primarily a decrease in maintenance costs (not to absolute zero) and a
significant decrease in unexpected breakdowns (not their complete elimination).
4. Using of standards is possible only with special machines, for which the special standards
exist.
It is not possible to simply define limit vibration values in general for a wide range of machines.
However, it is possible to create the standards for special machines (e.g. turbines), and these
standards are a strong diagnostic tool. General standards have a character of recommendation on
how to define the limit values. The way how to find the good condition values is to use measured
values of new or repaired machine. Also you can ask the machine producer for them.
5. Shortening of an interval between measurements means more successful prevention of
unexpected failures.
8
Further technical and contact information can be found at www.adash.com