RUGGEDCOM RSG907R
Installation Guide
Technical Specifications
This section provides important technical specifications related to the device.
CONTENTS
•
Section 5.1, "Power Supply Specifications"
•
Section 5.2, "Failsafe Alarm Relay Specifications"
•
Section 5.3, "Supported Networking Standards"
•
Section 5.4, "Fiber Optic Ethernet Port Specifications"
•
Section 5.5, "Operating Environment"
•
Section 5.6, "Mechanical Specifications"
•
Section 5.7, "Dimension Drawings"
Section 5.1
Power Supply Specifications
NOTE
When determining cable lengths, make sure the minimum input voltage for the power supply is
provided at the power source.
Hazardous Environments
Power
Supply Type
LO
HI
a
Current consumption may vary based on configuration.
Power Supply Specifications
Input Voltage
Minimum
Maximum
11.1 VDC
55 VDC
100 VDC
270 VDC
100 VAC
240 VAC
Internal
Fuse Rating
Nominal
12 VDC, 24
5 A
VDC, 48 VDC
125 VDC,
3.15 A
250 VDC
110 VAC,
3.15 A
220 VAC
Chapter 5
Technical Specifications
Maximum Power
Isolation
Consumption
1.5 kVDC
13.4 W
5 kVDC
15.3 W
5 kVDC
15.5 W
a