Technical Specifications
This section provides important technical specifications related to the device.
5.1
General specifications
Insulation
Overvoltage category
5.2
Power Supply Specifications
Supply Type
12-24 VDC
HI (125/250
HI (110/230
a
(T) denotes time-delay fuse
b
This is the same power supply for both AC and DC.
5.3
Failsafe Alarm Relay Specifications
Note
The following specifications are for Class-2 circuits only.
Maximum Switching Voltage
RUGGEDCOM RS900G
Equipment Manual, 10/2023, C79000-G8976-1025-10
Power
Minimum
Input
10 VDC
24 VDC
18 VDC
48 VDC
37 VDC
88 VDC
b
VDC)
85 VAC
b
VAC)
30 VDC
80 VDC
30 VAC
Class I
OVC II
Maximum
Fuse Rating
Input
36 VDC
3.15A (T)
36 VDC
3.15A (T)
72VDC
3.15A (T)
300 VDC
3.15A (T)
265 VAC
Rated Switching Current
1 A
0.3 A
Isolation
Maximum
Consumption
a
1.5 kVDC
a
1.5 kVDC
a
1.5 kVDC
a
4 kVAC
5.5 kVDC
Isolation
1500 V
for 1 minute
rms
5
Power
10 W
21