RUGGEDCOM RSG907R
Installation Guide

Device Management

This section describes how to connect to and manage the device.
CONTENTS
Section 3.1, "Connecting to the Device"
Section 3.2, "Configuring the Device"
Section 3.1

Connecting to the Device

The following describes the various methods for accessing the RUGGEDCOM ROS console and Web interfaces
on the device. For more detailed instructions, refer to the RUGGEDCOM ROS User Guide for the RUGGEDCOM
RSG907R.
IMPORTANT!
Ethernet cables should be only be connected/disconnected in a non-hazardous area, or when the
device is not energized.
Console Port
Connect a workstation directly to the USB Type-B console port to access the boot-time control and RUGGEDCOM
ROS interfaces. The console port provides access to RUGGEDCOM ROS's console interface.
IMPORTANT!
Console ports are intended to be used only as a temporary connection during initial configuration or
troubleshooting.
NOTE
For Microsoft Windows users, the RUGGEDCOM USB Serial Console driver must be installed on the users
workstation before connecting via the USB Type-B console port. For more information, refer to the
RUGGEDCOM ROS User Guide for the RUGGEDCOM RSG907R.
Use the following settings to connect to the port:
Speed
Data Bits
Stop Bit
Parity
Flow Control
Connecting to the Device
57600 baud
8
1
None
Off
Chapter 3
Device Management
23