Siemens SIMATIC NET RUGGEDCOM RSG2300F Installation Manual

Siemens SIMATIC NET RUGGEDCOM RSG2300F Installation Manual

Rugged ethernet switches
Hide thumbs Also See for SIMATIC NET RUGGEDCOM RSG2300F:

Advertisement

Quick Links

Installation Manual
SIMATIC NET
Rugged Ethernet Switches
RUGGEDCOM RSG2300F
Edition
04/2021
https://www.siemens.com

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC NET RUGGEDCOM RSG2300F

  • Page 1 Installation Manual SIMATIC NET Rugged Ethernet Switches RUGGEDCOM RSG2300F Edition 04/2021 https://www.siemens.com...
  • Page 2 Preface Introduction Installing the Device SIMATIC NET Device Management Rugged Ethernet Switches RUGGEDCOM RSG2300F Communication Ports Technical Specifications Installation Manual Certification 04/2021 C79000-G8976-1347-09...
  • Page 3 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 4: Table Of Contents

    Accessing Documentation ....................... v Registered Trademarks ......................v Warranty ..........................v Training ..........................vi Customer Support ........................vi Contacting Siemens ....................... vii Introduction ........................... 1 Feature Highlights ....................1 Description ......................2 Required Tools and Materials ................. 3 Decommissioning and Disposal ................3 Cabling Recommendations ..................
  • Page 5 Table of Contents 4.4.1 Installing a GBIC Optical Port ................27 4.4.2 Removing a GBIC Optical Port ................28 Technical Specifications ...................... 31 Power Supply Specifications ................31 Failsafe Relay Specifications ................31 Supported Networking Standards ................ 31 Copper Ethernet Port Specifications ..............32 Fiber Optic Ethernet Port Specifications ...............
  • Page 6: Preface

    Warranty Siemens warrants this product for a period of five (5) years from the date of purchase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
  • Page 7: Training

    Siemens Sales representative. Customer Support Customer support is available 24 hours, 7 days a week for all Siemens customers. For technical support or general information, contact Siemens Customer Support through any of the following methods: Online Visit http://www.siemens.com/automation/support-request...
  • Page 8: Contacting Siemens

    Contacting Siemens • Submit SRs or check on the status of an existing SR • Contact a local Siemens representative from Sales, Technical Support, Training, etc. • Ask questions or share knowledge with fellow Siemens customers and the support community...
  • Page 9 Preface Contacting Siemens viii RUGGEDCOM RSG2300F Installation Manual, 04/2021, C79000-G8976-1347-09...
  • Page 10: Introduction

    Introduction The RUGGEDCOM RSG2300F is a rugged, fully managed, modular Ethernet switch specifically designed to operate reliably in electrically harsh and climatically demanding utility substation, railway and industrial environments. The RUGGEDCOM RSG2300F’s superior rugged hardware design coupled with the embedded Rugged Operating System (ROS) provides improved system reliability and advanced cyber security and networking features, making it ideally suited for creating Ethernet networks for mission-critical, real-time, control applications.
  • Page 11: Description

    Introduction 1.2 Description • Zero-Packet-Loss™ technology • -40 to 85 °C (-40 to 185 °F) operating temperature (no fans) • Conformal coated printed circuit boards (optional) • 18 AWG galvanized steel enclosure • Hazardous Location Certification: Class 1 Division 2 Universal Power Supply Options •...
  • Page 12: Required Tools And Materials

    Introduction 1.3 Required Tools and Materials Mode Color/State Description Status Green (Solid) Link detected Green (Blinking) Link activity No link detected Duplex Green Full duplex mode Orange Half duplex mode No link detected Speed Green (Solid) 100 Mbps Green (Blinking) 1000 Mbps Orange (Solid) 10 Mbps No link detected...
  • Page 13: Cabling Recommendations

    Siemens also does not recommend using copper Ethernet ports to interface with devices in the field across distances that could produce high levels of ground potential rise (i.e. greater than 2500 V), during line-to-ground fault conditions.
  • Page 14: Supported Fiber Optic Cables

    Introduction 1.5.3 Supported Fiber Optic Cables Cabling 1000Base- Required Action Category TX Compliant Verify TIA/EIA-568-A compliance. No action required. New installations should be designed with Category 5e or higher. No action required. > 6 Connector and wiring standards to be determined. Follow these recommendations for copper data cabling in high electrical noise environments: •...
  • Page 15 Introduction 1.5.3 Supported Fiber Optic Cables RUGGEDCOM RSG2300F Installation Manual, 04/2021, C79000-G8976-1347-09...
  • Page 16: Installing The Device

    This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens AG could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
  • Page 17: General Procedure

    Visually inspect each item in the package for any physical damage. Verify all items are included. Note If any item is missing or damaged, contact Siemens for assistance. Mounting the Device The RUGGEDCOM RSG2300F is designed for maximum mounting and display flexibility.
  • Page 18: Mounting The Device To A Rack

    Installing the Device 2.3.1 Mounting the Device to a Rack Note For detailed dimensions of the device with either rack, DIN rail or panel hardware installed, refer to "Dimension Drawings (Page 35)". 2.3.1 Mounting the Device to a Rack The RUGGEDCOM RSG2300F can be secured to a standard 48 cm (19 in) rack using separately purchased rack mount adapters.
  • Page 19: Mounting The Device On A Din Rail

    Installing the Device 2.3.2 Mounting the Device on a DIN Rail To secure the device to a standard 48 cm (19 in) rack, do the following: Note The device can be ordered with the communication ports located at the front or rear of the device.
  • Page 20: Mounting The Device To A Panel

    Installing the Device 2.3.3 Mounting the Device to a Panel To mount the device to a DIN rail, do the following: Align the adapters with the DIN rails and slide the device into place. Panel/DIN Rail Adapter DIN Rail Screw Figure 2.2 DIN Rail Mounting Install one of the supplied screws on either side of the device to secure the adapters to the DIN rails.
  • Page 21: Connecting The Failsafe Alarm Relay

    Installing the Device 2.4 Connecting the Failsafe Alarm Relay To mount the device to a panel, do the following: Place the device against the panel and align the adapters with the mounting holes. Screw Panel/DIN Rail Adapter Figure 2.3 Panel Mounting Install the supplied screws to secure the adapters to the panel. Connecting the Failsafe Alarm Relay The failsafe relay can be configured to latch based on alarm conditions.
  • Page 22: Connecting Power

    Installing the Device 2.5 Connecting Power Normally Open Common Normally Closed Figure 2.4 Failsafe Alarm Relay Wiring Connecting Power The RUGGEDCOM RSG2300F supports a single or dual redundant AC and/or DC power supplies. The RUGGEDCOM RSG2300F can be equipped with either a screw-type or pluggable terminal block, which provides power to both power supplies.
  • Page 23: Connecting Ac Or Dc Power

    Installing the Device 2.5.1 Connecting AC or DC Power • It is recommended to provide a separate circuit breaker for each power supply module. • Equipment must be installed according to applicable local wiring codes and standards. 2.5.1 Connecting AC or DC Power To connect a single high AC, high DC or low DC power supply to the device, do the following: NOTICE...
  • Page 24 Installing the Device 2.5.1 Connecting AC or DC Power Connect the positive wire from the power source to the positive/live (+/L) terminal on the terminal block. Screw-Type Terminal Block Pluggable Terminal Block Jumper Positive/Live (+/L) Terminal Negative/Neutral (-/N) Terminal (-/N) Surge Ground Terminal Chassis Ground Terminal Chassis Ground Connection Figure 2.5...
  • Page 25: Wiring Examples

    Installing the Device 2.5.2 Wiring Examples Using a #6 ring lug and #6-32 screw, secure the ground terminal on the power source to the chassis ground connection on the device. Make sure the lug is tightened to 1.7 N·m (15 lbf·in). Stainless Steel Stud #6-32 Screw #6 Ring Lug...
  • Page 26 Installing the Device 2.5.2 Wiring Examples Figure 2.7 Single AC Power Supply Figure 2.8 Single DC Power Supply RUGGEDCOM RSG2300F Installation Manual, 04/2021, C79000-G8976-1347-09...
  • Page 27 Installing the Device 2.5.2 Wiring Examples Figure 2.9 Dual AC Power Supply Figure 2.10 Dual DC Power Supply RUGGEDCOM RSG2300F Installation Manual, 04/2021, C79000-G8976-1347-09...
  • Page 28 Installing the Device 2.5.2 Wiring Examples Figure 2.11 Dual AC/DC Power Supply RUGGEDCOM RSG2300F Installation Manual, 04/2021, C79000-G8976-1347-09...
  • Page 29 Installing the Device 2.5.2 Wiring Examples RUGGEDCOM RSG2300F Installation Manual, 04/2021, C79000-G8976-1347-09...
  • Page 30: Device Management

    Device Management This section describes how to connect to and manage the device. Connecting to the Device The following describes the various methods for accessing the RUGGEDCOM RSG2300F console and Web interfaces on the device. For more detailed instructions, refer to the RUGGEDCOM ROS Configuration Manual for the RUGGEDCOM RSG2300F.
  • Page 31: Configuring The Device

    Device Management 3.2 Configuring the Device Name Description Comment RJ45 Male DB9 Female Ring Indicator   The DSR, DCD and DTR pins are connected together internally. The CTS and RTS pins are connected together internally. RI is not connected. Communication Ports Connect any of the available Ethernet ports on the device to a management switch and access the RUGGEDCOM RSG2300F console and Web interfaces via the device's IP address.
  • Page 32: Communication Ports

    Communication Ports The RUGGEDCOM RSG2300F can be equipped with various types of communication ports to enhance its abilities and performance. Module Assignment Figure 4.1 Module Assignment Each type of module has a specific location in the RUGGEDCOM RSG2300F chassis: • Slots 1 and 2 support any combination of two-port fiber or copper Ethernet modules up to 100 Mbps •...
  • Page 33: Copper Ethernet Ports

    Communication Ports 4.1 Copper Ethernet Ports   LED State Description Yellow (Solid) Link established Yellow (Blinking) Link activity No link detected Port LED Figure 4.2 Port LEDs Copper Ethernet Ports The RUGGEDCOM RSG2300F supports several 10/100/1000Base-TX Ethernet ports that allow connection to standard Category 5 (CAT-5) unshielded twisted-pair (UTP) cables with either RJ45 male connectors.
  • Page 34: Fiber Optic Ethernet Ports

    Communication Ports 4.2 Fiber Optic Ethernet Ports Name Description 10/100Base-TX 1000Base-TX BI_DB+ Transmit Data+ or Bi- Directional Pair B+ Reserved (Do Not Connect) BI_DC+ Transmit Data+ or Bi- Directional Pair C+ Reserved (Do Not Connect) BI_DC- Receive Data- or Bi- Directional Pair C- BI_DB- Transmit Data- or Bi- Directional Pair B-...
  • Page 35: Sfp Transceivers

    RUGGEDCOM SFP Transceiver Catalog [https:// support.industry.siemens.com/cs/ca/en/view/109482309]. IMPORTANT Only use SFP transceivers approved by Siemens for RUGGEDCOM products. Siemens accepts no liability as a result of performance issues related in whole or in part to third-party components. GBIC Optic Ethernet Ports GBIC (Gigabit Interface Converter) optic Ethernet ports are available with SC (Standard or Subscriber Connector) connectors.
  • Page 36: Installing A Gbic Optical Port

    To install a GBIC optical port, do the following: NOTICE Electrical hazard – risk of damage to equipment Use only components certified by Siemens with RUGGEDCOM products. Damage to the module and device may occur if compatibility and reliability have not been properly assessed.
  • Page 37: Removing A Gbic Optical Port

    Communication Ports 4.4.2 Removing a GBIC Optical Port Squeeze the latches on either side of the port and insert the port into the socket. GBIC Optical Port Module Socket Locking Latch Figure 4.9 Installing a GBIC Optical Port Release the latches and make sure the port is locked in place. NOTICE Only remove the dust plug when ready to connect a cable to the GBIC optical port.
  • Page 38 Communication Ports 4.4.2 Removing a GBIC Optical Port Disconnect the cable from the port and install the dust cap to the cable end. Squeeze the latches on either side of the port and pull it from the socket. Socket GBIC Optical Port Locking Latch Figure 4.10 Removing a GBIC Optical Port...
  • Page 39 Communication Ports 4.4.2 Removing a GBIC Optical Port RUGGEDCOM RSG2300F Installation Manual, 04/2021, C79000-G8976-1347-09...
  • Page 40: Technical Specifications

    Technical Specifications This section details the specifications and operating conditions of the device. Power Supply Specifications The RUGGEDCOM RSG2300F can be equipped with the following power supplies: NOTICE Electrical hazard – risk of damage to the device Make sure power input to the device is within the specified input range. Power Input Range Internal Fuse...
  • Page 41: Copper Ethernet Port Specifications

    Note • Maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a Siemens sales associate when determining maximum segment distances. • All optical power numbers are listed as dBm averages.
  • Page 42: Fiber Optic Ethernet Port Specifications

    14.2 Typical. Typical distance. The maximum distance is greatly dependent on factors such as cable type, the number of connectors and number of splices. Consult a Siemens sales associates when determining maximum distances. Fast Ethernet (10/100 Mbps) Optical Specifications Mode...
  • Page 43: Operating Environment

    All optical power numbers are listed as dBm averages. Typical distance. The maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a Siemens sales associates when determining maximum segment distances. GBIC Gigabit (1 Gbps) Transceiver Specifications Note GBIC transceivers have a temperature range of -40 to 85 °C (-40 to 185 °F), unless...
  • Page 44: Mechanical Specifications

    Technical Specifications 5.7 Mechanical Specifications Mechanical Specifications Weight 5.2 kg (11.5 lbs) Ingress Protection IP30 Enclosure 18 AWG Galvanized Steel Dimension Drawings Note All dimensions are in millimeters, unless otherwise stated. Note Dimensional tolerances are in accordance with ISO 2768-mK, unless otherwise stated.
  • Page 45 Technical Specifications 5.8 Dimension Drawings 32.77 21.08 11.68 479.29 470.4 461.0 Figure 5.2 Rack Mount Dimensions RUGGEDCOM RSG2300F Installation Manual, 04/2021, C79000-G8976-1347-09...
  • Page 46 Technical Specifications 5.8 Dimension Drawings 11.7 10.4 476.3 486.4 Figure 5.3 Panel and DIN Rail Mount Dimensions RUGGEDCOM RSG2300F Installation Manual, 04/2021, C79000-G8976-1347-09...
  • Page 47 Technical Specifications 5.8 Dimension Drawings RUGGEDCOM RSG2300F Installation Manual, 04/2021, C79000-G8976-1347-09...
  • Page 48: Certification

    UL 62368-1 Information Technology Equipment – Safety Part 1: General Requirements 6.1.2 European Union (EU) This device is declared by Siemens AG to comply with essential requirements and other relevant provisions of the following EU directives: • EN 62368-1 Information Technology Equipment – Safety – Part 1: General Requirements •...
  • Page 49: Fcc

    Methods of Measurement The device is marked with a CE marking and can be used throughout the European community. A copy of the CE Declaration of Conformity is available from Siemens AG. For contact information, refer to "Contacting Siemens (Page vii)".
  • Page 50: Iso

    Quality management systems – Requirements 6.1.7 RoHS This device is declared by Siemens AG to meet the requirements of the following RoHS (Restriction of Hazardous Substances) directives for the restricted use of certain hazardous substances in electrical and electronic equipment: •...
  • Page 51 Certification 6.2 EMC and Environmental Type Tests EMC Type Tests per IEC 61850-3 Test Description Test Levels Severity Levels IEC 61000-4-2 Enclosure Contact ±8 kV Enclosure Air ±15 kV IEC 61000-4-3 Radiated RFI Enclosure Ports 20 V/m   IEC 61000-4-4 Burst (Fast Signal Ports ±4 kV @ 2.5 kHz  ...
  • Page 52 Certification 6.2 EMC and Environmental Type Tests Test Description Test Levels Severity Levels AC Power Ports 2 kV   HV Impulse Signal Ports 5 kV (Fail-Safe   Relay Output) DC Power Ports 5 kV   AC Power Ports   Only applicable to functional earth connections separated from the safety earth connection. EMC Immunity Type Tests per IEEE 1613 Note The RUGGEDCOM RSG2300F meets Class 2 requirements for an all-fiber...
  • Page 53 Certification 6.2 EMC and Environmental Type Tests Test Description Test Levels IEC 60068-2-2 Dry Heat Test Bd 85 °C (185 °F), 16 Hours IEC 60068-2-30 Humidity (Damp Heat, Cyclic) Test Db 95% (Non-Condensing), 55 °C (131 °F), 6 Cycles IEC 60068-2-6 Vibration 2g @ 10-150 Hz, 2 hours per axis IEC 60255-21-1...
  • Page 54 Further Information Siemens RUGGEDCOM https://www.siemens.com/ruggedcom Industry Online Support (service and support) https://support.industry.siemens.com Industry Mall https://mall.industry.siemens.com Siemens AG Digital Industry Process Automation Postfach 48 48 90026 NÜRNBERG GERMANY...

This manual is also suitable for:

Ruggedcom rsg2300f

Table of Contents