Cisco IE-4000 Software Configuration Manual page 126

Industrial ethernet switch
Hide thumbs Also See for IE-4000:
Table of Contents

Advertisement

Performing Switch Administration
Additional References
Configuring MAC Threshold Notification Traps: Example
This example shows how to specify 172.20.10.10 as the NMS, enable the MAC address threshold notification feature,
set the interval time to 123 seconds, and set the limit to 78 per cent.
Switch(config)# snmp-server host 172.20.10.10 traps private mac-notification
Switch(config)# snmp-server enable traps mac-notification threshold
Switch(config)# mac address-table notification threshold
Switch(config)# mac address-table notification threshold interval 123
Switch(config)# mac address-table notification threshold limit 78
Adding the Static Address to the MAC Address Table: Example
This example shows how to add the static address c2f3.220a.12f4 to the MAC address table. When a packet is received
in VLAN 4 with this MAC address as its destination address, the packet is forwarded to the specified port:
Switch(config)# mac address-table static c2f3.220a.12f4 vlan 4 interface GigabitEthernet1/17
Configuring Unicast MAC Address Filtering: Example
This example shows how to enable unicast MAC address filtering and to configure the switch to drop packets that have
a source or destination address of c2f3.220a.12f4. When a packet is received in VLAN 4 with this MAC address as its
source or destination, the packet is dropped:
Switch(config)# mac
Additional References
The following sections provide references related to switch administration:
a
ddress-table static c2f3.220a.12f4 vlan 4 drop
122

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IE-4000 and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Ie-5000Ie-4010

Table of Contents

Save PDF