4.5.3

Parameter description:

Number
1
Amplifier setting
Used to select the absolute position detection.
0
0
2
Regenerative brake resistor
Servo amplifier 200V
0
0
CAUTION:
Wrong setting may cause the regenerative brake option to burn.
NOTE:
If the regenerative brake option selected is not for use with the servo amplifier, parameter error (37) occurs.
3
Reserved
Do not change this parameter.
4
Reserved
Do not change this parameter.
5
Reserved
Do not change this parameter.
Tab. 4-13: Parameter list details (1)
4 - 14
Symbol
AMS
0
Positioning
0: Standard (incremental)
1: Absolute position detection system
REG
Regenerative selection brake option
00: No brake resistor
01: FR-RC, FR-BU
05: MR-RFH220-40
08: MR-RFH400-13
09: MR-RFH400-13
0B: MR-RFH400-6.7
0C: MR-RFH400-6.7
10: MR-RFH75-40
11: MR-RFH75-40
Initial value
Unit
0000
0000
Servo amplifier 400V
0
0
Regenerative selection brake option
00: No brake resistor
01: FR-RC-H , FR-BU-H
80: MR-RB3H-4
81: MR-RB5H-4/MR-PWR-T-600-80
82: MR-RB3G-4
83: MR-RB5G-4/MR-PWR-T-600-47
84: MR-RB34-4
85: MR-RB54-4/MR-PWR-T-600-26
86: MR-RB1L-4/MR-PWR-T-150-270
87: MR-RB3M-4/MR-PWR-T-400-120
0080
0000
1
Parameter
Setting range
Refer description
Refer description