Synchronizing the System Time of the
V Switch on the PTP function on all devices whose time you want to syn-
chronize using PTP.
V If there is no reference clock available, designate a Switch as reference
clock, and set the system time as precisely as possible.

7.3.3 Configuring PTP

In the dialog Time:PTP:Global, you can enable/disable the function
and make the PTP settings on the devices MS20/30 and Power MICE
which are to apply to all ports.
PTP Global
U
V Select the Time:PTP:Global dialog.
V Switch on the function in the "Operation IEEE 1588 / PTP" frame.
V If you have designated this Switch to be the PTP reference clock,
click in the "Configuration IEEE 1588 / PTP" frame in the "Prefer-
red Master" line the value "true".
D
By selecting "Reinitialize" you restart the synchronization of the
local clock.
D
Configuration
Clock Mode: Mode of the local clock.
Possible options are:
– ptp-mode-Boundary-clock,
– ptp-mode-simple-ptp (without runtime correction, without
determining the best clock) Select this mode, if the Switch has no
time stamp unit (RT module).
Preferred Master: Defines the local clock as the Preferred
Master.
Basic - L3P
Release 3.1 06/07
7.3 Precison Time Protocol