Product Certifications
March 2016
2. The enclosure may be made from aluminum alloy and
given a protective polyurethane paint finish; however,
care should be taken to protect it from impact or
abrasion when located in Zone 0 environment. The
polyurethane paint finish may constitute an
electrostatic hazard and must only be cleaned with a
damp cloth.
3. When the equipment is installed, particular
precautions must be taken to ensure taking into
account the effect of process fluid temperature, that
the ambient temperature of the electrical housing of
the equipment meets the marked protection type
temperature range.
ATEX Type n Certification
EN 60079-0: 2012
EN 60079-11: 2012
EN 60079-15: 2010
N1
Certification No. Baseefa05ATEX0085X
ATEX Marking
II 3 G Ex nA ic IIC T5 Gc (-50 °C ≤ Ta ≤ 70 °C) 4-20
mA HART
II 3 G Ex nA ic IIC T5 Gc (-50 °C ≤ Ta ≤ 60 °C) Fieldbus
Maximum Working Voltage = 42 VDC 4-20 mA HART
Maximum Working Voltage = 32 VDC Fieldbus
Special conditions for safe use (X):
1. When fitted with 90V transient suppressors (T1
Option), the equipment is not capable of passing the
500V isolation test. This must be taken into account
upon installation.
2. The enclosure may be made from aluminum alloy
with a protective polyurethane paint finish. The
polyurethane paint finish may constitute and
electrostatic hazard and must only be cleaned with a
damp cloth.
3. When the equipment is installed, particular
precautions must be taken to ensure, taking into
account the effect of process fluid temperature, that
the ambient temperature of the electrical housing of
the equipment meets the marked protection type
temperature range.
ATEX flameproof certification
EN 60079-0: 2009
EN 60079-1: 2007
EN 60079-11: 2012
EN 60079-26: 2007
Product Certifications
www.aotewell.com
E1
Certificate: KEMA99ATEX3852X
Integral Flowmeter marked:
Remote Transmitter marked:
with meter body marked:
42 VDC Max 4-20 mA HART
32 VDC Max Fieldbus
U
Installation instructions:
1. The cable and conduit entry devices shall be of a
certified flameproof type Ex d, suitable for the
conditions of use and correctly installed.
2. Unused apertures shall be closed with suitable
blanking elements.
3. When the ambient temperature at the cable or
conduit entries exceed 60 °C, cables suitable for at
least 90 °C shall be used.
4. Remote mounted sensor; in type of protection Ex ia
IIC, only to be connected to the associated
Rosemount 8800D Vortex Flowmeter electronics. The
maximum allowable length of the interconnecting
cable is 152 m (500 ft).
Special conditions for safe use (X):
1. For information regarding the dimensions of the
flameproof joints, the manufacturer shall be
contacted.
2. The Flowmeter shall be provided with special
fasteners of property class A2-70 or A4-70.
3. Units marked with "Warning: Electrostatic Charging
Hazard" may use non-conductive paint thicker that
0.2 mm. Precaution shall be taken to avoid ignition
due to electrostatic charge on the enclosure.
Combined ATEX certifications
K1
E1, I1, and N1 Combination

B.5.3 International IECEx certifications

Intrinsic Safety
IEC 60079-0: 2011
IEC 60079-11: 2011
I7
Certificate No. IECEx BAS 05.0028X
Ex ia IIC T4 Ga (-60 °C ≤ T
Ex ia IIC T4 Ga (-60 °C ≤ T
4-20 mA HART
entity parameters
U
(1)
I
i
sales@aotewell.com
00809-0100-4772, Rev FA
II 1/2 G Ex d [ia] IIC T6 Ga/Gb (-50 °C ≤ Ta ≤ 70 °C)
II 2(1) G Ex d [ia Ga] IIC T6 Gb (-50 °C ≤ Ta ≤ 70 °C)
II 1 G Ex ia IIC T6 Ga (-50 °C ≤ Ta ≤ 70 °C)
= 250V
m
≤ 70 °C) 4-20 mA HART
a
≤ 60 °C) Fieldbus
a
Fieldbus entity
parameters
= 30 VDC
U
= 30 VDC
i
i
(1)
= 185 mA
I
= 300 mA
i
Industry Automation
Reference Manual
FISCO input
parameters
U
= 17.5 VDC
i
(1)
I
= 380 mA