Process-wetted materials
Wetted material selection
Ensure that the process fluid is compatible with the
meter body wetted materials when specifying the
Rosemount 8800D Vortex Flowmeter. Corrosion will
shorten the life of the meter body. Because of the wide
variety of processes and applications, it is impossible to
guarantee material compatibility in a given process
without preforming corrosion tests under actual
operatiing conditions. Therefore, the final decision of
material selection resides with the end user.
Note
For accurate material identification, perform a
Positive Material Identification (PMI) test on a
machined surface.
Meter body
CF-3M cast stainless steel
N06022 wrought nickel alloy and CW2M cast nickel
alloy
6A Duplex stainless steel
WCB or LCC cast carbon steel
Flanges
316/316L stainless steel
Nickel alloy N06022 Weld Neck
A105N forged carbon steel
LF2 forged carbon steel
UNS S32760 wrought duplex stainless steel
Collars
Nickel alloy N06022
316/316L stainless steel
Surface finish of flanges and collars
Standard: To the requirements of the applicable flange
standard
Smooth: 63 to 125 m inches
(1.6 to 3.1 m meters) Ra roughness
Process connections
Mounts between the following flange configurations:
ASME B16.5 (ANSI): Class 150, 300, 600, 900, 1500
DIN: PN 10, 16, 25, 40, 64, 100, 160
JIS: 10K, 20K, and 40K
Weld-end: Schedule 10, 40, 80, and 160
Mounting
Integral (standard)
Electronics are mounted on meter body.
114
www.aotewell.com
Remote (optional)
Electronics may be mounted remote from the meter
body. Interconnecting coaxial cable available in
nonadjustable 10, 20, and 30 ft (3,0, 6,1, and 9,1 m)
lengths. Consult factory for non-standard lengths up to
75 ft (22,9 m). Remote mounting hardware includes a
polyurethane painted, carbon steel pipe mount bracket
with one carbon steel u-bolt.
Armored remote cables are also available in lengths of
10, 20, 33, 50 and 75 feet. The armored remote option
comes standard with an aluminum gland to connect
the cable to the meter and electronics. A stainless steel
gland is provided when ordered in conjunction with a
stainless steel electronics housing.
Temperature limitations for integral mounting
The maximum process temperature for integral mount
electronics is dependent on the ambient temperature
where the meter is installed. The electronics must not
exceed 185°F (85°C). The following is for reference,
please note that the pipe was insulated with 3 inches of
ceramic fiber insulator.
Figure A-1. Rosemount 8800 Vortex Flowmeter
Shows combinations of ambient and process temperatures
needed to remain at or below 185°F (85°C) housing temperature
200 (93)
180 (82)
160 (71)
140 (60)
120 (49)
100 (38)
Meter and pipe insulated with 3 inches of ceramic fiber insulation.
Horizontal Pipe and Vertical meter position.
sales@aotewell.com
Specifications and Reference Data
Ambient/Process Temperature Limits
80 (27)
60 (16)
Process Temperature °F (°C)
Specifications and Reference Data
Industry Automation
March 2016
185°F Housing
Temperature Limit