Chapter 4 Maintenance

<Reference>
When any abnormality is found, refer to 'Chapter 5 Troubleshooting' and report the contents to the
maintenance in charge. If the rectification method is not clear, please contact our office.
Please make a copy of this checklist, check each inspection item in the respective square, and file
the list for record.

4-1 Daily Inspection

Be sure to inspect the following items prior to operation and confirm that there is no
abnormality.
Operating this device without inspection or in an abnormal condition can result in
serious injury or death.
Check list (Daily inspection)
Check
column
Dangerous parts of the machine cannot be reached without passing through the sensing area
of this device.
Some part of operator's body remains in the sensing area when operation is done with
dangerous parts.
The calculated safety distance has been maintained or exceeded during installation.
There is no damage to the safety guard or protective structure.
There is no defect, fold, or damage in the wiring.
The corresponding connectors have been connected securely.
No dirt or scratches exist on the light emitting surface.
The test rod is not deformed or defective.
The operation indicator (green) of the emitter and the OSSD indicator (green) of the receiver
light up when no object is present in the sensing area. The control output (OSSD 1, OSSD 2)
is in ON status.
At this time, the effect of external noise can be inspected. In case external noise affects the
operation, remove its cause and re-inspect.
The test rod can (ø30mm) be detected at three positions, directly in front of the emitter (A),
midway between the emitter and the receiver (B), and directly in front of the receiver (C).
The OSSD indicator (red) of the receiver and the operation indicator (red) of the emitter
continues to light up as long as the test rod is present in the sensing area from (A) to (C).
With the machine in the operating condition, the dangerous parts operate normally when no
object is present in the sensing area.
With the machine in the operating condition, the dangerous parts stop immediately when the
test rod is inserted into the sensing area at any of the three positions, directly in front of the
emitter (A), midway between the emitter and the receiver (B), and directly in front of the
receiver (C).
The dangerous parts remain stopped as long as the test rod is present in the sensing area.
The dangerous parts stop immediately when the power supply of this device is turned OFF.
The control output (OSSD 1, OSSD 2) must turn OFF when the emission halt input line is
open, or connected to 0 to +1.5V. At this time, the effect of external noise can be inspected. In
case external noise affects the operation, remove its cause and re-inspect.
- 70 -
© Panasonic Industrial Devices SUNX Co., Ltd. 2013 MJE-SF4A No.0038-55V