ON: When the periodic test transmission interval occurs, the test transmission will alternate
between being sent to the primary and secondary receivers with each test transmission
interval.
OFF: When the periodic test transmission interval occurs, the test transmission will be sent to
the programmed receivers, based on the settings of the periodic test transmission reporting
codes.
[8] Cellular Low Signal Trouble.
Default (OFF)
This option masks the Low Signal trouble from the Cellular trouble event.
ON: A Cellular Trouble event is transmitted to receiver when the radio signal level falls below
threshold level (average CSQ level is 4 or less).
OFF: A Cellular Trouble event is not transmitted to receiver when the radio signal level falls
below threshold level (average CSQ level is 4 or less).
[006] System Toggle Options 2
[3] Reserved. ( ).
[4] Cellular 1 Receiver Enabled.
Default
(ON).
ON: Cellular Receiver 1 is enabled.
OFF: Cellular Receiver 1 is disabled.
[5] Cellular 2 Receiver Enabled.
Default
(ON).
ON: Cellular Receiver 2 is enabled.
OFF: Cellular Receiver 2 is disabled.
[6] Reserved ( ).
[7] DLS Over Cellular.
Default (ON).
NOTE: Program this toggle as OFF if you want to completely disable DLS from using the
Cellular path.
ON: DLS is enabled on the Cellular path.
OFF: DLS is disabled on the Cellular path.
NOTE: If this Toggle is OFF, DLS sessions occur on the Cellular path, regardless of Primary
Path set in section [005], toggle option [4]. If it is ON, the Communicator connects to
the Primary path first for DLS. If the session fails, the Secondary path is used.
[8] Reserved ( ).
P
ROGRAMMING
[010] System Toggle Option
Default (Disable)
[1] This bit is used to enable/disable two way audio over Cellular.
[011] Installer Code
Default (CAFE)
Program your installer code for this Communicator module. The installer code is required
when programming the Communicator module. Valid range: 0000 - FFFF.
[012] DLS Incoming Port
Default (0BF6/3062)
The DLS Incoming Local Port (listening port) is the port DLS 5 uses when connecting to the
Communicator. If a router or gateway is used, it must be programmed with a Transmission
Control Protocol (TCP) port forward for this port to the Communicator module IP address.
Valid range: 0000 - FFFF.