Siemens SIPROTEC 7UT613 series Manual page 586

Differential protection
Hide thumbs Also See for SIPROTEC 7UT613 series:
Table of Contents

Advertisement

A Appendix
No.
Description
033.2413
Undervoltage protection is
ACTIVE (Undervolt. ACT)
033.2491
Undervoltage: Not avail. for this
obj. (U< err. Obj.)
033.2492
Undervoltage: error assigned VT
(U< err. VT)
033.2502
>BLOCK undervoltage protection
U<< (>BLOCK U<<)
033.2503
>BLOCK undervoltage protection
U< (>BLOCK U<)
033.2521
Undervoltage U<< picked up
(U<< picked up)
033.2522
Undervoltage U< picked up (U<
picked up)
033.2551
Undervoltage U<< TRIP (U<<
TRIP)
033.2552
Undervoltage U< TRIP (U< TRIP) Undervoltage
034.2404
>BLOCK overvoltage protection
(>BLOCK O/V)
034.2411
Overvoltage protection is
switched OFF (Overvolt. OFF)
034.2412
Overvoltage protection is
BLOCKED (Overvolt. BLK)
034.2413
Overvoltage protection is
ACTIVE (Overvolt. ACT)
034.2491
Overvoltage: Not avail. for this
obj. (U> err. Obj.)
034.2492
Overvoltage: error VT assign-
ment (U> err. VT)
034.2502
>BLOCK overvoltage protection
U>> (>BLOCK U>>)
034.2503
>BLOCK overvoltage protection
U> (>BLOCK U>)
034.2521
Overvoltage U>> picked up (U>>
picked up)
034.2522
Overvoltage U> picked up (U>
picked up)
034.2551
Overvoltage U>> TRIP (U>>
TRIP)
034.2552
Overvoltage U> TRIP (U> TRIP)
044.2404
>BLOCK Thermal Overload Pro-
tection (>BLK ThOverload)
044.2411
Thermal Overload Protection
OFF (Th.Overload OFF)
044.2412
Thermal Overload Protection
BLOCKED (Th.Overload BLK)
044.2413
Thermal Overload Protection
ACTIVE (Th.Overload ACT)
044.2421
Thermal Overload picked up
(O/L Th. pick.up)
044.2451
Thermal Overload TRIP (ThOver-
load TRIP)
044.2491
Th. Overload Not available for
this obj. (O/L Not avail.)
044.2494
Th. Overload err.:adverse
Adap.factor CT (O/L Adap.fact.)
586
Function
Undervoltage
OUT
ON
OFF
Undervoltage
OUT
ON
Undervoltage
OUT
ON
Undervoltage
SP
ON
OFF
Undervoltage
SP
ON
OFF
Undervoltage
OUT
*
Undervoltage
OUT
*
Undervoltage
OUT
*
OUT
*
Overvoltage
SP
*
Overvoltage
OUT
ON
OFF
Overvoltage
OUT
ON
OFF
Overvoltage
OUT
ON
OFF
Overvoltage
OUT
ON
Overvoltage
OUT
ON
Overvoltage
SP
ON
OFF
Overvoltage
SP
ON
OFF
Overvoltage
OUT
*
Overvoltage
OUT
*
Overvoltage
OUT
*
Overvoltage
OUT
*
Therm. Overload
SP
*
Therm. Overload
OUT
ON
OFF
Therm. Overload
OUT
ON
OFF
Therm. Overload
OUT
ON
OFF
Therm. Overload
OUT
ON
OFF
Therm. Overload
OUT
*
Therm. Overload
OUT
ON
Therm. Overload
OUT
ON
Log Buffers
Configurable in Matrix
ON
*
LED
OFF
*
*
LED
*
*
LED
ON
*
LED BI
OFF
ON
*
LED BI
OFF
ON
*
LED
OFF
ON
*
LED
OFF
ON
*
LED
ON
*
LED
*
*
LED BI
*
*
LED
ON
*
LED
OFF
ON
*
LED
OFF
*
*
LED
*
*
LED
ON
*
LED BI
OFF
ON
*
LED BI
OFF
ON
*
LED
OFF
ON
*
LED
OFF
ON
*
LED
ON
*
LED
*
*
LED BI
*
*
LED
ON
*
LED
OFF
*
*
LED
*
*
LED
ON
m
LED
OFF
*
*
LED
*
*
LED
IEC 60870-5-103
BO
74
32
1
Yes
BO
BO
BO
74
8
1
Yes
BO
74
6
1
Yes
BO
74
37
2
Yes
BO
74
33
2
Yes
BO
74
40
2
Yes
BO
74
39
2
Yes
BO
BO
74
65
1
Yes
BO
74
66
1
Yes
BO
74
67
1
Yes
BO
BO
BO
74
21
1
Yes
BO
74
20
1
Yes
BO
74
71
2
Yes
BO
74
68
2
Yes
BO
74
73
2
Yes
BO
74
70
2
Yes
BO
167
3
1
Yes
BO
167
11
1
Yes
BO
167
12
1
Yes
BO
167
13
1
Yes
BO
167
17
1
Yes
BO
167
21
2
Yes
BO
BO
7UT613/63x Manual