Midtronics CELLTRON MAX Instruction Manual

Midtronics CELLTRON MAX Instruction Manual

Universal stationary battery analyzer
Table of Contents

Advertisement

Quick Links

CELLTRON®
U
s
niversal
tationary
B
a
attery
nalyzer
For testing stationary batteries in
UPS systems, power utility, and
telecommunications industries
INSTRUCTION MaNUal
MAX
March 2010
167-087C

Advertisement

Table of Contents
loading

Summary of Contents for Midtronics CELLTRON MAX

  • Page 1 March 2010 167-087C CELLTRON® niversal tationary attery nalyzer For testing stationary batteries in UPS systems, power utility, and telecommunications industries INSTRUCTION MaNUal...
  • Page 3: Table Of Contents

    Jar Voltage Threshold Description Post Per Jar Test capability Test Mode Measurements Reference Test range Test Type CELLTRON MAX Kit Temperature Data AC Ripple Kit Accessories DC Float V Hot Keys DC Float A Connections And Data Ports SAVE AND TEST...
  • Page 4 Mode Display Contrast Level Backlight Time Time Out Straps Internal Battery Speaker Temperature Test Mode Quick Test Gen Batt Capac Mgr Multi SP Chapter 9: Hot Keys Quick Test www.midtronics.com Midtronics Inc. 7000 Monroe Street Willowbrook, IL 60527 • •...
  • Page 5: Safety Guidlines

    Incorrect reassembly may result in a risk of electric shock or fire. 1.4 Test batteries in a dry, well-ventilated area. 1.5 Do not expose the tester to rain or snow. Midtronics Inc. 7000 Monroe Street Willowbrook, IL 60527 www.midtronics.com •...
  • Page 6: Testing Precautions

    • Battery posts, terminals, and related accessories contain lead and lead compounds, chemicals known to cause cancer and birth defects or other reproductive harm. Wash hands after handling. www.midtronics.com Midtronics Inc. 7000 Monroe Street Willowbrook, IL 60527 • •...
  • Page 7: Product Specifications

    CELLTRON Product Specifications Model Number Display CMA-7000 CELLTRON MAX (analyzer); CELLTRON MAX Kit LCD—FSTN (x2) Applications 66.52 mm x 33.25 mm (2.62 in x 1.31 in), 128 x 64 pixels, 40- degree viewing angle, contrast ratio 8, green LED backlight...
  • Page 8: Chapter 1: Analyzer Overview

    The CELLTRON MAX tests lead-acid batteries that are 2, 4, 6, 8, 10, 12, 14, and 16 V. The analyzer can test batteries providing The analyzer features (2) backlit graphical LCD’s, a digital power to a load (in service) or not providing power (not in multimeter, and a thumb drive and transfer to a PC.
  • Page 9: Celltron Max Kit

    CELLTRON CEllTRON MaX Kit Tester cables with locking connectors for interchangeable probes and clamps Tester cable storage Collapsable Probe Extenders Adapter CEllTRON MaX Tester Cable IR Printer Midtronics Inc. 7000 Monroe Street Willowbrook, IL 60527 www.midtronics.com • •...
  • Page 10: Data

    Extension rods for reaching and testing jars in confined spaces Midtronics printer with an AC Handheld printer with infrared receiver for data transmitted by the CELLTRON MAX; adapter (120 Vac, 60 Hz) includes battery charger (output 10.2 Vdc, 800 mA) for charging the printer’s NiMH...
  • Page 11: Hot Keys

    (0) for jar and straps Reports View Hierarchy, Trend, String Data, Jar Data; Print String and Jar Data Help Help on present screen; Hold for 3 seconds and screens will rotate 180 degree Midtronics Inc. 7000 Monroe Street Willowbrook, IL 60527 www.midtronics.com • •...
  • Page 12: User Interface

    User Interface Scroll Boxes Scroll boxes contain selections (usually The CELLTRON MAX user interface is a icon-based system numerical values) that extend above arranged in a series of menus. Menus may have several and below the box that contains them.
  • Page 13: Site Setup

    Measures voltage within a range of 0 to 18 Vdc. Estimates voltage within a range of 0 to 20 V peak-to-peak AC. Voltage trace with time and frequency measurements. Calculates the direct current flow through a circuit. Midtronics Inc. 7000 Monroe Street Willowbrook, IL 60527 www.midtronics.com • •...
  • Page 14: Chapter 2: Reference Values

    Determine a reference value • created. If you create a reference value for a jar model, e-mail the value and information to net@midtronics.com or fax it to Set options in the UTILITIES SETUP menu • 630-323-7752 (Attn: Reference value list). Set test parameters in the BATTERY SETUP menu •...
  • Page 15: Testing Sample Jars

    String Summary average If you cannot obtain a reference value for a string, test the string and use the average conductance value (AVG. MHOS) in the STRING SUMMARY as your reference value. If jars in the string have been replaced recently, test the new jars, especially if they correlate to the HIGH jar value in STRING SUMMARY. Midtronics Inc. 7000 Monroe Street Willowbrook, IL 60527 www.midtronics.com • •...
  • Page 16: Chapter 3: Site Setup

    You can also add Plants as outlined procedure to create a new Plant. in the NEW SITE section of this chapter. From the Main Menu, use the ARROW keys to highlight the EXISTING SITE icon and press the SELECT ITEM soft key. www.midtronics.com Midtronics Inc. 7000 Monroe Street Willowbrook, IL 60527 • •...
  • Page 17: Create Plant

    EN- TER soft key to select it. The character will appear on the lower screen. Repeat this process to complete the line. Midtronics Inc. 7000 Monroe Street Willowbrook, IL 60527 www.midtronics.com •...
  • Page 18: Tech Id

    Use ARROW keys on the screen to move the cursor. Press the F2 key to save your changes and return to the TEST SETUP screen. Use the ARROW keys to increase or decrease the thresh- old value. www.midtronics.com Midtronics Inc. 7000 Monroe Street Willowbrook, IL 60527 • •...
  • Page 19: Post Per Jar

    TEST SETUP screen without saving any changes. CONDUCTANCE screen appears on the lower screen. Use the ARROW keys to select UPPER or LOWER CONDUC- TANCE THRESHOLD and press the ENTER key. . Midtronics Inc. 7000 Monroe Street Willowbrook, IL 60527 www.midtronics.com •...
  • Page 20: Test Mode

    ENTER.. internal analysis of the results. 4) BASE LINE TESTING SELECTED Use the ARROW keys to highlight REFERENCE and press the ENTER key. A screen appears to establish the reference. www.midtronics.com Midtronics Inc. 7000 Monroe Street Willowbrook, IL 60527 • •...
  • Page 21: Test Type

    Use this option to save configuration into the tester memory and then to perform battery test. SAVE AND CONTINUE Use this option to save configuration into the tester memory and then continue with testing. Midtronics Inc. 7000 Monroe Street Willowbrook, IL 60527 www.midtronics.com • •...
  • Page 22: Chapter 4: Cq Sync

    From the Main Menu use the ARROW keys to highlight NOTE: Measurement data can only be the CQ SYNC icon and press the SELECT ITEM soft key. viewed using the Midtronics Celltraq® En- Highlight the DOWNLOAD icon and press the SELECT terprise Battery Asset Management System ITEM soft key.
  • Page 23: Delete

    Press the DELETE soft key to complete the deletion or press the CANCEL soft key to return to the CQ SYNC menu. Midtronics Inc. 7000 Monroe Street Willowbrook, IL 60527 www.midtronics.com • •...
  • Page 24: Chapter 5: Retest Jar

    TEST. The tester will begin retesting the volt- age and conductance of the selected jar using the set- tings saved in the Test Setup. During this time a represen- tation of the jar is displayed on the upper screen. www.midtronics.com Midtronics Inc. 7000 Monroe Street Willowbrook, IL 60527 • •...
  • Page 25: Temperature

    The LED indicators at the top of the tester will also illuminate to show a FAIL / WARN / PASS. Select PRINT to send the results to the IR printer or select EXIT to complete the retest and return to the Main Menu. Midtronics Inc. 7000 Monroe Street Willowbrook, IL 60527 www.midtronics.com •...
  • Page 26: Chapter 6: Dmm

    CELLTRON Chapter 6: DMM The CELLTRON MAX features a DMM with four digi- Use the ARROW keys to highlight the AC VOLTS icon tal meters including a DC Voltmeter, AC Voltmeter, and press the SELECT ITEM soft key.. The AC VOLTMETER Scope, and DC Current.
  • Page 27: Adjust Time/Div

    Press ENTER to save the new scale value or BACK to re- turn DMM menu without saving any changes. Autoscale Volts/Div When selected, the Autoscale funtion automatically rescales the graphic displayed on the top screen. Midtronics Inc. 7000 Monroe Street Willowbrook, IL 60527 www.midtronics.com • •...
  • Page 28: Chapter 7: Battery Manager

    Use ARROW keys to change the reference value and press F2 soft key to save. Follow the onscreen prompts to insert the desired manu- facturer information. Press ENTER to save your changes or BACK to go exit www.midtronics.com Midtronics Inc. 7000 Monroe Street Willowbrook, IL 60527 • •...
  • Page 29: Chapter 8: Utilities

    Although the date and time are set at the factory, you may need to make changes based on your time zone. Midtronics Inc. 7000 Monroe Street Willowbrook, IL 60527 www.midtronics.com •...
  • Page 30: Language

    Use the up or down ARROW keys to select the desired setting. The CELLTRON MAX can display screens and print re- Press the SAVE soft key to save your changes or the BACK ports using seven selectable languages including:...
  • Page 31: Contrast Level

    Battery Option is used for combined battery conductance and strap resistance measurements. CELLTRON MAX option is used for measuring strap resistance only. From the Main Menu highlight the UTILITY icon and press the SELECT ITEM soft key.
  • Page 32: Speaker

    Use the ARROW keys to highlight the TEMPERATURE icon, and press ENTER. The EDIT TEMPERATURE screen appears on the lower screen. Use the up or down ARROW keys to select the parameter you want to edit. www.midtronics.com Midtronics Inc. 7000 Monroe Street Willowbrook, IL 60527 • •...
  • Page 33: Quick Test

    ERATOR BATTERY and FLEET VEHICLE. save. Press the SAVE soft key to save your changes or the BACK soft key to return to the Main Menu without saving your changes. Midtronics Inc. 7000 Monroe Street Willowbrook, IL 60527 www.midtronics.com • •...
  • Page 34: Chapter 9: Hot Keys

    Use the REPORTS hot key to go directly to the Reports Menu. Help The HELP hot key gives direct access to assistance and information for the testers active function. www.midtronics.com Midtronics Inc. 7000 Monroe Street Willowbrook, IL 60527 • •...
  • Page 35: Chapter 9: Troubleshooting

    To replace a damaged a probe tip: printer, digital temperature gun, or the PC software application, 1. Grasp the probe tip with pliers at the top of the sleeve. refer to their manuals or call Midtronics Customer Service for assistance. (See Patents, Limited Warranty, Service.) Screen does not power on during testing (no text/graphics) Do not damage probe when removing  Check the connection to the jar.
  • Page 36: Test Results Do Not Print Or Print Incorrectly

    If the printer is not receiving data, remove the When a printer fault occurs, the STATUS LED flashes. You can printer and the CELLTRON MAX from direct sunlight. If the identify the fault by the number of sequential flashes: printed characters are not clear or are partially missing, recharge the battery and reprint.
  • Page 37 Limited Warranty The CELLTRON MAX is warranted to be free of defects in materials and workmanship for a period of one year from date of purchase. Midtronics will, at our option, repair or replace the unit with a remanufactured unit. This limited warranty applies only to the CELLTRON ULTRA analyzer, and does not cover any other equipment, static damage, water damage, overvoltage damage, dropping the unit, or damage resulting from extraneous causes including owner misuse.

This manual is also suitable for:

Cma-7000

Table of Contents