child lock setting, press Time key first to display Up/Down key at the main interface, and then press Set and Down
key together for 5 seconds to enter child lock setting. After setting child lock, Up/Down key will keep displaying for
the convenience of cancellation of child lock.
Parameter Inquiry
(1) Keep pressing
for 5 seconds to enter parameter inquiry. Unit No. is displayed on 88 area of clock while
data type is displayed on 88 area of timer. Unit No. is displayed on the first two "88" fields of clock while data
type is displayed on the first two "88" fields of timer. The data type includes A, b, C, d, E and F. The current data
is displayed behind date type. For example, ambient temp. of 00 unit is 16 degree, then "00
Press
to choose different type of data from A, b, C, d, E and F.
Data
Type meaning
A
Indoor sensor Tai temp.
b
Indoor sensor Tc1 temp.
C
Indoor sensor Tc2 temp.
d
Indoor unit PMV opening/2
E
Indoor unit address
F
Indoor unit central address
(2) In parameter inquiry state, press
(3) In parameter inquiry state, press the
(4) In parameter inquiry state, press
corresponding functions will work.
(5) In parameter inquiry state, press "ON/OFF" , it will exit the current state directly and then turn on/off.
Unit No. Setting
(1) Entering: Press
key for 10 seconds to enter unit No. setting/ inquiring.
(2) Setting is available when the communication address between indoor and outdoor unit is flashing if the indoor
unit's dip switch can set the address, then use
set the address, the communication address between indoor and outdoor unit is static, which can only be inquired.
(3) Wired controller's address is displayed before the colon of clock on the top-left corner, ranging from 0 to 15 and
displayed in decimal system.
(4) The communication address between indoor and outdoor unit is displayed on the top-left corner. The default
value is the current unit's address, selecting other indoor units by the
(5) Central address is displayed on top-right corner which cannot be edited.
(6) Press
key to confirm and exit the setting after changing the communication address of indoor unit. If press
other keys or no operation in 10 seconds, it will automatically exit and keep previous setting. If press
key, exit and the current setting is invalid. If press "ON/OFF", turn on/off the unit directly and the current setting is
invalid.
Static Pressure Grade Inquiry and Adjustment Function
(1) In the state of ON and non screen saving state, press Fan + Set keys for 5s to enter static pressure grade
adjustment state with static pressure icon flashing and current static pressure grade statically displaying. Press
key to change static pressure grade, then press Set key to confirm.
(2) The unit No. will display by two 8 segments after colon on the top-left corner, and static pressure grade will
display by two 8 segments after colon on the top-right corner. Press Time key to shift unit No..
(3) Unit No. will show decimally from 00-15. Static pressure will be shown decimally from 01-04.
(4) In query and adjustment state, if there is no screen saving, press ON/OFF key to quit current state and turning
on/off unit, with changed values not being saved.
(5) Static pressure is the inquired value with non-volatile memory invalid.
Communication with Central Controller
(1) The controller displays
(2) When
statically displays, all keys except "ON/OFF" of wired controller are invalid. central icon will disappear if
no central control signal from indoor unit.
(3) When receiving locking signal from indoor unit,
key to change the unit No. address in the group.
key again or have no operation for 10 seconds to exit.
or
can exit the parameter inquiry and press above keys again, their
to adjust within the range of 0-3F. If the indoor dip switch cannot
to show central control mode after receiving central control signal from indoor unit;
statically display, all keys are invalid.
System
Actual value, decimal sys.
Actual value, decimal sys.
Actual value, decimal sys.
Actual value, decimal sys.
Actual value, hexadecimal sys.
Actual value, hexadecimal sys.
.
228
Smart Power
A 16" is displayed.