Smart Power
No.
Symbol
23
Ht.F
24
Ht.H
25
Ht.I
26
Ht.J
27
qut
28
Frq
29
opN
29
I.FN
30
o. FN
31
tAo
32
tc
33
td
34
tE
35
tS
36
tdr
37
Idr
38
tH
39
tAI
40
TCI
41
tSt
42
UN
43
r32
44
OiL
LED digital display
Explanation
Heat mode of SCOP test condition F
Heat mode of SCOP test condition H
Heat mode of SCOP test condition I
Heat mode of SCOP test condition J
Quit
Frequency (speed of compressor, equals revolutions per
second (RPS) ) .
Electronic expansion valve opening
Indoor unit fan speed level
Indoor unit fan speed level
Temperature of outdoor ambient
Temperature of outdoor condenser
Temperature of outdoor discharge
Temperature of outdoor defrost
Temperature of outdoor suction
Temperature of compressor driver module
Current of the compressor
Temperature of heat water (reserved)
Temperature of indoor ambient
Temperature of indoor condenser
Setting temperature on indoor unit
UN=UNIT, 1UN means with 1 indoor unit:
2UN means with 2 indoor unit, MAXI application
Refrigerant R32
Unit gets compressor oil recycling mode