Smart Power
• Improper tightening of bolts would lead to the faults shown in
the following figure.
• After tightening the bolts, if there is a clearance between the
ceiling and the trim panel, please readjust the height of the
indoor unit.
If the elevation level of the indoor unit and drain pipe are not
affected, you can adjust the height of the indoor unit through the
corner pore on the trim panel. Please keep the unit horizontal
in the process of adjustment, or else water leakage is easy to
occur.
• Please do not swing the louver blade by hand, or else the
blade mechanism would be damaged.
6) Connection of trim panel. Connect the black lead-out terminal
of the panel to the black lead-out terminal of the indoor unit
housing.
7) When the installation of panel is complete, please fix the four
(4) angle trim panels.
• Hang and tighten the strap of the angle trim panel on the
shackle of the trim panel, as shown in the figure.
• Fix the angle trim panel on the trim panel.