Haier Smart Power Series Service Manual page 101

Table of Contents

Advertisement

Smart Power
Power cable
Communication cable
Connecting cable
Power source
Start current
Unit model (color)
Compressor
Fan
Heat
Outdoor
exchanger
unit
Dimension
Drainage pipe (material, I.D./O.D.)
Refrigerant control method
Defrosting
Volume of accumulator
Sound power Noise level (H-M-L)
Sound pressure Noise level (H-M-L)
Type of four way valve
Material of reduce noise
Crankcase heater power
Weight (Net/Shipping)
Refrigerant
Piping
Pipe
Connecting method
Between I.D &O.D
Norminal condition:
Indoor temperature (cooling) : 27DB (°C)/19WB (°C) , Indoor temperature (heating) : 20DB (°C)
Outdoor temperature (cooling) : 35DB (°C)/24WB (°C) , Outdoor temperature (heating) : 7DB (°C)/6WB (°C)
The noise level will be measured in the third octave band limited values, using a Real Time Analyser calibrated
sound intensity meter. It is a sound pressure noise level.
Item
Model/Manufacture/place
Oil model
Oil charging
Type
Type×Number
Speed
Fan motor input power
Fan motor output power
Air-flow (H-M-L)
Type/Diameter
Row/Fin pitch
Total area
External (W×D×H)
Package (W×D×H)
Type/Charge
Maximum pipe length
without recharge refrigerant
Recharge quantity
Liquid
Gas
MAX. Drop
MAX. Piping length
Model
N, V, Hz
A
1UH125P1ERG (WHITE)
MNB42FFAMC-L (MITSUBISHI
ELECTRIC COMPRESSOR CO., LTD)
CC
Twin Rotary
r/min
kW
kW
3
m
/h
mm
2
m
mm×mm×mm
mm×mm×mm
mm
mm/mm
ELECTRONIC VAVE 3.0mm
L
dB (A)
dB (A)
W
kg/kg
g
g/m
mm
mm
m
m
99
1UH140P1ERK
2
H05RN-F 5G 2.5mm
/
2
H05RN-F 4G 2.5mm
3N~, 380~415, 50/60Hz
3
PVE (FV50S)
1600
1
Axial×2
700±40
0.12×2
0.10×2
7000
TP2M/Φ7.0
2
1.4
1.17
950×370×1350
1090×480×1500
None
Auto
4.0
70
53
SHF-20D-46
XPE
38
108/121
R410A/3700
30
45
9.52
15.88
Flared
30
75