Sensors
Gas type
Measure-
ment range
(ppm)
Combustible
Catalytic
0-100% LEL
gases
AsH
Arsine
1.00
3
Cl
Chlorine
10.0
2
Chlorine
ClO
3.00
2
dioxide
CO
Carbon
100
monoxide
300
1000
Carbon
CO
0-5% vol.
2
dioxide
COCl
Phosgene
1.00
2
ETO
Ethylene
30.0
oxide
H
Hydrogen
2000
2
Hydrogen
30.0
H
S
2
sulfide
100
1000
HCl
Hydrogen
30.0
chloride
100
HCN
Hydrogen
30.0
cyanide
HF
Hydrogen
10.0
fluoride
100
NH
Ammonia
3
1000
5000
NO
Nitric oxide
100
300
1000
NO
Nitrogen
30.0
2
dioxide
O
Oxygen
0-30% vol.
2
O
Ozone
1.00
3
PH
Phosphine
1.00
3
SiH
Silane
50.0
4
Sulfur
10.0
SO
2
dioxide
30.0
100
CH
Cl
Chloro-
500
3
methane
CH
Cl
Dichloro-
500
2
2
methane
Freon R12
1% vol.
Freon R22
2000
Freon R123
2000
FX56
2000
Freon R134a
2000
Freon R11
1% vol.
Freon R23
1% vol.
Freon R143a
2000
Freon R404a
2000
Freon R507
2000
Freon R410a
1000
Explosion
Intrinsically
Temp.
% RH Accuracy (ppm) Average
-proof
-safe
range (°C)
sensor
sensor
-25 to +55 0-95
-20 to +40 20 - 90 +/- 0.05
-20 to +40 10 - 90 +/- 0.4
-20 to +40 10 - 90 +/- 0.3
-20 to +50 15 - 90 +/- 3
-25 to +55 0 - 95 +/- 3%
-20 to +40 15 - 90 +/- 0.05
-20 to +50 15 - 90 +/- 1.0
-20 to +50 15 - 90 +/- 5%
-25 to +50 15 - 90 +/- 1.5
-20 to +40 15-95 +/- 0.4
-25 to +40 15-95 +/- 0.3
-10 to +30 20 - 80 +/- 5%
-20 to +40 15 - 90 +/- 5
-20 to +50 15 - 90 +/- 2
-20 to +50 15-90 +/-0.8
-20 to +50 15 - 90 0.4% vol.
0 to +40
10 - 90 +/- 0.03 (from 0-
-20 to +40 20 - 90 +/- 0.05
-20 to +40 20 - 95 +/- 1.0
-20 to +50 15 - 90 +/- 0.7
-20 to +55 20 - 95 +/- 15% (from 20-
-20 to +55 20 - 95 +/- 15% (from 20-
-20 to +55 20 - 95 +/- 15% (from 20-
-20 to +55 20 - 95 +/- 15% (from 20-
-20 to +55 20 - 95 +/- 15% (from 20-
-20 to +55 20 - 95 +/- 15% (from 20-
-20 to +55 20 - 95 +/- 15% (from 20-
-20 to +55 20 - 95 +/- 15% (from 20-
-20 to +55 20 - 95 +/- 15% (from 20-
-20 to +55 20 - 95 +/- 15% (from 20-
-20 to +55 20 - 95 +/- 15% (from 20-
-20 to +55 20 - 95 +/- 15% (from 20-
-20 to +55 20 - 95 +/- 15% (from 20-
13 – Technical Specifications
Resp. time
service life
T50/T90 (s)
(months)
+/-1% LEL
40
6/15 (CH4)
(from 0-70% LEL)
18
30/120
24
10/60
24
20/120
40
15/40
(0-100 range)
48
11/30
12
60/180
36
50/240
24
30/50
36
15/30
(0-30 range)
24
30/150
(0-30 range)
18
30/120
(0-10 range)
12
40/90
25/70
24
+/- 20
20/60
+/- 150 or 10%
60/180
36
10/30
(0-100 range)
24
30/60
28
6/15
(from 15-22% O2)
18
40/120
0.2 ppm) +/- 0.05
(from 0.2-1 ppm)
18
30/120
18
25/120
36
15/45
(0-10 range)
40
25/90
70% PE)
40
25/90
70% PE)
40
25/90
70% PE)
40
25/90
70% PE)
40
25/90
70% PE)
40
25/90
70% PE)
40
25/90
70% PE)
40
25/90
70% PE)
40
25/90
70% PE)
40
25/90
70% PE)
40
25/90
70% PE)
40
25/90
70% PE)
40
25/90
70% PE)
Storage
conditions
and time
(b)
(a)
(a)
(a)
(a)
(a)
(c)
(a)
(a)
(a)
(a)
(c)
(c)
(a)
(a)
(a)
(a)
(c)
(a)
(a)
(a)
(d)
(d)
(d)
(d)
(d)
(d)
(d)
(d)
(d)
(d)
(d)
(d)
(d)