HOW TO ADJUST THE SENSOR BY REMOTE CONTROL

After unlocking, the
red LED flashes and the
sensor can be adjusted
by remote control.
If necessary, select the corresponding detection field before selecting the parameter and changing the
value. The second LED indicates the detection field.
...
MOTION
....
PRESENCE
..
SAFETY

HOW TO ADJUST THE SENSOR BY LCD

Select your Language before entering the
first LCD menu.
Within the first 30 seconds of power-on of the sensor
or later in the diagnostics menu.
Access advanced adjustments.
More
Parameter
Displayed value = Factory value
Value
75.5916.02 LZR-WIDESCAN 20180112
75.5916.02 LZR-WIDESCAN 20180112
75.5916.02 LZR-WIDESCAN 20180112
75.5916.02 LZR-WIDESCAN 20180112
If the red LED flashes quickly after unlocking, enter an
access code from 1 to 4 digits. If you do not know the
access code, cut and restore the power supply.
Within 1 minute, you can access the sensor without
any code.
...
....
..
Enter the LCD menu.
Select a folder, parameter, or value.
SHORT
Confirm a value and exit edit mode.
PRESS
Activate red spots on floor.
PRESS
2X
Launch POSITION WIZARD.
LONG
PRESS
Activate red spots on floor
Teach-in: install
Teach-in: pull cord
Presettings
Restoring
Password
Enter a Password if necessary.
X X X X
Go to the Diagnostics menu.
>Diagnostics
Parameter
Value
Displayed value = Saved value
To end an adjustment
session, always lock the
sensor.
...
Return to previous menu or
display.
Scroll up or down.