Product Data 16V4000G74F, Application 3D; 16V4000G74S, Application 3D - MTU 12V4000Bx4 Operating Instructions Manual

Table of Contents

Advertisement

4.26 Product data 16V4000G74F, application 3D; 16V4000G74S,
application 3D
Key
DL Reference value: Continuous power. Continuously attainable power at standard conditions.
BL Reference value: Fuel stop power. Maximum engine power. Not continuously attainable in some appli-
cations (margin for load fluctuations).
A Design value. Value required to design an external system (plant).
R Guideline value. Typical average value for information, only partially suitable for design purposes.
L Limit value. Value which must not be violated (lower limit value, min. value / upper limit value, max.
value), not suitable for design purposes.
N Not yet defined value. Value has not yet been defined or will not be defined.
- Not applicable. Module is not applicable to the given product type.
X Applicable. Module is applicable to the given product type.
> Actual value must be greater than the specified value.
< Actual value must be less than the specified value.
* Not sufficiently validated value (+/- 10% tolerance).
** Not sufficiently validated value (+/- 5% tolerance).
ID
Product type
1
16V4000G74F
2
16V4000G74F
3
16V4000G74F
4
16V4000G74S
5
16V4000G74S
Reference conditions
ID
Intake air temperature
Charge-air coolant tempera-
ture
Barometric pressure
Site altitude above sea level
158 | Technical Data | MS15038/01E 2018-11
Application
Speed
Power generation
1500 rpm
3D standby power,
50 Hz
fuel stop power, IFN
Power generation
1500 rpm
3D standby power,
50 Hz
fuel stop power, IFN
Power generation
1500 rpm
3D standby power,
50 Hz
fuel stop power, IFN
Power generation
1800 rpm
3D standby power,
60 Hz
fuel stop power, IFN
Power generation
1800 rpm
3D standby power,
60 Hz
fuel stop power, IFN
1
°C
25
°C
55
mbar
1000
m
100
Nominal pow-
er
1965 kW
Ref. 25 °C/55 °C
2635 bhp
Optimized fuel con-
sumption
1965 kW
Ref. 25 °C/45 °C
2635 bhp
NEA Singapore for
ORDE
1965 kW
Ref. 25 °C/45 °C
2635 bhp
China NRMM Stage III
(GB20891-2014)
2280 kW
Ref. 25 °C/45 °C
3058 bhp
EPA Stationary EMERG
T2 (40CFR60)
EPA Nonroad T2 Comp
(40CFR89)
2280 kW
Ref. 25 °C/55 °C
3058 bhp
Optimized fuel con-
sumption
2
3
4
25
25
25
45
45
45
1000
1000
1000
100
100
100
5
25
55
1000
100

Advertisement

Table of Contents
loading

This manual is also suitable for:

12v4000gx416v4000bx416v4000gx4

Table of Contents