1066 – AL Inj. Drift Limit 2 Cyl. B5
Cause
The drift correction for
energization (start and duration)
of injector B5 has violated limit 2.
The injector has reached its
maximum drift limit.
1067 – AL Inj. Drift Limit 2 Cyl. B6
Cause
The drift correction for
energization (start and duration)
of injector B6 has violated limit 2.
The injector has reached its
maximum drift limit.
1068 – AL Inj. Drift Limit 2 Cyl. B7
Cause
The drift correction for
energization (start and duration)
of injector B7 has violated limit 2.
The injector has reached its
maximum drift limit.
1069 – AL Inj. Drift Limit 2 Cyl. B8
Cause
The drift correction for
energization (start and duration)
of injector B8 has violated limit 2.
The injector has reached its
maximum drift limit.
1070 – AL Inj. Drift Limit 2 Cyl. B9
Cause
The drift correction for
energization (start and duration)
of injector B9 has violated limit 2.
The injector will soon reach its
maximum drift limit.
1071 – AL Inj. Drift Limit 2 Cyl. B10
Cause
The drift correction for
energization (start and duration)
of injector B10 has violated limit
2. The injector will soon reach its
maximum drift limit.
216 | Troubleshooting | MS15038/01E 2018-11
Corrective action
u Replace injector (→ Page 244).
Corrective action
u Replace injector (→ Page 244).
Corrective action
u Replace injector (→ Page 244).
Corrective action
u Replace injector (→ Page 244).
Corrective action
u Replace injector (→ Page 244).
Corrective action
u Replace injector (→ Page 244).