Product Data 16V4000M93L - MTU 12V4000M93 series Operating Instructions Manual

Table of Contents

Advertisement

3.8 Product data 16V4000M93L

Explanation:
DL Reference value: Continuous power
BL Reference value: Fuel stop power
I Index
A Design value
G Guaranteed value
R Guideline value
L Limit value, up to which the engine can be operated, without change (e.g. of power setting).
N Not yet defined value
- Not applicable
X Applicable
Reference condition
Designation
Application group
Intake air temperature
Raw water inlet temperature
Barometric pressure
Site altitude above sea level
Power-related data (power ratings are net brake power as per ISO 3046)
Designation
Rated engine speed
Fuel stop power ISO 3046
Site conditions (for max. power)
Designation
Intake depression (new filter)
Intake depression, max.
Model-related data (basic design)
Designation
Cylinder arrangement: V angle
Bore
Stroke
Cylinder displacement
Total displacement
Number of inlet valves per cylinder
Number of exhaust valves per cylinder
Raw water circuit (open circuit)
Designation
Pressure loss in engine-external raw water system, max.
82 | Technical Data | MS150047/05E 2018-08
I
Unit
Value
1DS
°C
25
°C
25
mbar
1000
m
100
I
Unit
Value
A
rpm
2100
A
kW
3440
I
Unit
Value
A
mbar
15
L
mbar
30
I
Unit
Value
Degrees
90
mm
170
mm
190
Liters
4.31
Liters
68.96
2
2
I
Unit
Value
L
bar
1.0