Exchanging Data Using SCADA and Other Software
EM Area Allocation
Specified
CS1W-LCB05
CS1D-CPU@@P
EM Bank
00000
System Common 20 words
Control/Operation Block
00020
10, 000 words
(Addresses 001 to 500)
10020
Reserved
2000 words
(Addresses 501 to 600)
12020
External Control Block
640 words except for
CS1D-CPU@@P
(Addresses 601 to 632)
12660
Reserved
1,360 words
(Addresses 633 to 700)
14020
System Use
700 words
700 addresses
14720
Reserved
280 words
System Common 20 words
15000
15020
Control/Operation Block
10, 000 words
(Addresses 001 to 500)
25020
Reserved
2000 words
(Addresses 501 to 600)
27020
External Control Block
640 words except for
CS1D-CPU@@P
(Addresses 601 to 632)
27660
Reserved
1,360 words
(Addresses 633 to 700)
29020
Real PV input value
monitor area
29520
Reserved
32767
Note
166
contain the new value. In this case, the data cannot be read properly.
To be sure that both ITEMs contain the correct data, read the 8-digit
value (such as an accumulated value) two times, compare the two 8-
digit values, and proceed only when the two values are equal.
2. Perform the same processing described above to verify the accuracy of 8-
digit values in the HMI area when reading or writing the values from the
CPU Unit instead of the SCADA Software.
Specified
CS1G-CPU43/44/45P
EM Bank
Send
00000
System Common 20 words Send
Control/Operation Block
00020
6000 words
(Addresses 001 to 300)
06020
Reserved
6640 words
12660
Reserved
1360 words
14020
System Use
700 words
700 addresses
Reserved
14720
280 words
System Common 20 words
Receive
15000
15020
Control/Operation Block
10,000 words
(Addresses 001 to 300)
21020
Reserved
6640 words
27660
Reserved
1,360 words
Send
29020
Real PV input value
monitor area
---
29320
Reserved
32767
CSV Output Functions for HMI Data Allocation Parameters (CX-Process
Tool Ver. 3.2 or Higher)
When CX-Process Tool Ver. 3.2 or higher is used, the HMI data allocation
parameters (indicating which tag or tag ITEM is to be allocated in which
address of the EM Area) can be output in CSV format.
Specified
CS1W-LCB01
CJ1G-CPU42P
EM Bank
00000
System Common 20 words Send
Control/Operation Block
00020
1000 words
(Addresses 001 to 050)
01020
Reserved
11,000 words
(Addresses 051 to 600)
12020
External Control Block
640 words (Not supported
by CJ1G-CPU@@P)
(Addresses 601 to 632)
12660
Reserved
1360 words
(Addresses 633 to 700)
14020
System Use
700 words
700 addresses
14720
Reserved
280 words
System Common 20 words
Receive
15000
15020
Control/Operation Block
1000 words
(Addresses 001 to 050)
16020
Reserved
11,000 words
(Addresses 051 to 600)
27020
External Control Block
640 words (Not supported
by CJ1G-CPU@@P)
(Addresses 601 to 632)
27660
Reserved
6856 words
Send
29020
Real PV input value
monitor area
---
29070
Reserved
32767
Section 3-4
---