Advanced Setup Table

Description
Step#
Available Modes
2
3
Backlight
4
Backlight Level
6
Current Service Filter Runtime Hours
7
Current Service Filter Calendar Days
11
Current Override Hours
12
Current UV Lamp Calendar Days
13
Current Humidifier Calendar Days
14
Set Service Filter Runtime Hours
15
Set Service Filter Calendar Days
16
Set UV Lamp Calendar Days
17
Set Humidifier Calendar Days
18
Language
19
Scrolling Method
Setpoint Limits
20
Max Heat Setpoint
21
Min Cool Setpoint
22
Cycles Per Hour
23
Compressor Minimum Off Minutes
24
Minimum Heat/Cool Setpoint Difference
25
Number Of Compressor Stages
26
Wired Sensor Use
38
Control To Temp Source
39
Humidity Only With Heat
40
Fan With Humidity Demand
41
Cool To Dehumidify
43
Maximum Dehum Overcool
44
F/C
56
Dry Contact Polarity
70
Dry Contact Use
71
Set Unoccupied Cool Setpoint
72
Set Unoccupied Heat Setpoint
73
35
8/29/13
Df = Factory Default Setting
-2200C-2
Pg#
Range
19
Heat/Cool/Auto/Off,
Heat/Cool/Off, Heat/Off,
Cool/Off
15
On, Off
15
Off-7 levels of brightness
18
0-1999
18
0-1999
18
0-1999
18
0-1999
0-1999
18
0-1950
18
18
0-720
18
0-720
18
0-720
15
English,Espanol,Francais
L-R Slow,L-R Fast,Word
16
L-R Slow,Word L-R Fast,
Whole Word L Slow,
Whole Word L Fast,
Whole Word Ctr Slow,
Whole Word Ctr Fast
No, Use, Force Current
19
Mode, Setpoints Frozen
35˚- 99˚
19
35˚- 99˚
19
20
No Limit, 2, 3, 4, 5, 6
20
0,3,5
20
0˚- 6˚
1 or 2
20
Indoor, Outdoor
20
Tstat, Remote
20
On,Off
21
Fan On,Fan Off
21
On, Off
21
0˚- 5˚
21
Fahrenheit, Celsius
21
Open, Closed
22
Pan, Unoccupied
22
35˚- 99˚
22
35˚- 99˚
22
PAGE 27
1:11 PM
Df
Heat/Cool/
Auto/Off
Off
Level 5
0
0
0
0
0
0
0
0
0
English
Whole
Word Ctr
Fast
No
80˚
65˚
6
5
1
Outdoor
Tstat
Off
Fan Off
Off
F
Open
Unoccupied
85˚
55˚