D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM TSTATD2200C-2 COMMERCIAL Non-Programmable Digital Thermostat with Humidity Control • Multi Stage 2+2 Owner's Manual Installation Instructions Commercial Use...
Page 2
(1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Thermostat TSTATD2200C-2 Tested to Comply with FCC Standards FOR HOME OR OFFICE USE...
Page 3
D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM Glossary of Terms Auto-Changeover: A mode in which the thermostat will turn on the heating or cooling based on room temperature demand. Cool Setpoint: The warmest temperature that the space should rise to before cooling is turned on (without regard to deadband). Deadband: The number of degrees the thermostat will wait, once a setpoint has been reached, before energizing heating or cooling.
D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM Get to Know Your Thermostat Front Panel Backlit LCD Display HUMIDITY MODE Scrolling Display PROGRAM HOLD TO SET Outdoor Heat or Cool OVERRIDE OVERRIDE Demand Indicator Red = Heat EMERGCY EMERGCY Green = Cool SET CLOCK HOLIDAY DISPLAY ACCESSORY SETUP RST FLTR...
Page 6
D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM Get to Know Your Thermostat Display Features Setup Step Stage Fan On Outdoor The scrolling display will be used to help you easily navigate the setup screens in the thermostat. Mode Indicators Selects the operational mode of the equipment. HEAT - Indicates the heating mode.
Page 7
D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM Get to Know Your Thermostat Display Features Setup Step Stage Fan On Outdoor Desired Set Temperature Indicates desired room temperature(s). 2nd Stage icon Indicates what stage of cooling or heating is currently energized. Setup Step icon Indicates the step number when the thermostat is in the setup mode.
Page 8
D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM Get to Know Your Thermostat Display Features Setup Step Stage Fan On Outdoor AuxHeat icon Indicates 2nd stage electric strip heat is being used when the thermostat is programmed for Heat Pump operation. Fan On icon Indicates constant, continuous fan operation.
D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM Quick Start During Setup and Programming: Press the UP or DOWN buttons to modify the selection. Press the MODE button to advance and confirm through the setup steps. Selecting the Heat or Cool Mode Select mode by pressing the MODE button. Heating Only - The HEAT setting indicates the temperature the room has to reach before the furnace will turn on to heat the room.
D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM Quick Start NOTE: Override may only be Using the Override Button used when the Dry Contact has forced the thermostat into the Unoccupied mode. Unoccupied Operation - During a Dry Contact forced unoccupied period pressing the OVERRIDE button will force the thermostat into the mode it was in before the Dry Contact forced it into the Unoccupied mode.
D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM Installation Instructions Remove & Replace the Old Thermostat To install the thermostat properly, please follow these step by step instructions. If you are unsure about any of these steps, call a qualified technician for assistance. Assemble tools: Flat blade screwdriver, wire cutters and wire strippers.
D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM Installation Instructions Wire Connections Wire Connections If the terminal designations on your old thermostat do not match those on the new thermostat, refer to the chart below or the wiring diagrams that follow. Install on the Wire from the new thermostat old thermostat...
Page 14
D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM Installation Instructions Explanation of Thermostat Jumpers Jumpers are located on the back of the thermostat RV=O GAS/ELEC RV=O GAS/ELEC ELEC RV=B HEATPUMP ELEC RV=B HEATPUMP This jumper configures the thermostat to control a conventional GAS/ELEC GAS/ELEC gas/electric system or a heat pump.
D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM Installation Instructions Sample Wiring Diagrams Conventional Heating and Cooling Systems 3 Wire, Heat Only 4 Wire, Cool Only Residential & Commercial 1 Stage Heating Residential & Commercial 1 Stage Cooling. with no Fan. 24VAC Power 24VAC Power 24VAC Common 24VAC Common 1st Stage Cool...
D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM Installation Instructions: Test Operation This thermostat has a diagnostic feature that enables testing of all outputs. This feature is contained in Technician Setup. To enter Technician Setup, press and hold the SETUP button for 5 seconds until all the icons appear.
D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM User Setup: Backlight Operation How to Change Settings in the Setup Screens To enter Advanced Setup, press the SETUP button, then press MODE. Use the UP or DOWN buttons to adjust the value of your selection. Press MODE to advance to the next setup step.
D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM User Setup: Scrolling Screen and Display Options Scrolling Display Method (Setup Step 19) This option allows the user to choose how the scrolling text is displayed. Options are: Scrolling Non-Scrolling Scroll Letters Slow Whole Words Slow Scroll Letters Fast Whole Words Fast Scroll Words Slow...
D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM User Setup Emergency Heat The Emergency Heat function is only available if your thermostat is set to control a Heat Pump. To initiate the Emergency Heat feature, Press and hold the EMERGCY HEAT button for 2 seconds. During Emergency Heat operation the thermostat will turn on the fan and auxiliary stages of heat when there is a demand for heat.
D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM User Setup: System Runtimes These setup steps allow the user to monitor equipment runtimes and program service alerts. Runtime hours or days appear here in the display. System Runtimes (Setup Steps 6-17) Setup Step Press the SETUP button, then press MODE repeatedly until the desired setup step appears.
D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM Installer Setup How to Change Settings in the Setup Screens To enter Advanced Setup, press the SETUP button, then press MODE. Use the UP or DOWN buttons to adjust the value of your selection. Press MODE to advance to the next setup step.
D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM Installer Setup Cycles Per Hour (Setup Step 23) The Cycles Per Hour setting may limit the number of times per hour your HVAC unit may energize. For example, at a setting of 6 cycles per hour the HVAC unit will only be allowed to energize once every 10 minutes.
D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM Installer Setup Humidity and Dehumidity (Setup Steps 40-44, 75-76) Humidity Only With Heat (Setup Step 40) - When this step is set to ON, Humidity will not run without a demand for Heat. Fan With Humidity Demand (Setup Step 41) - Specifies if the fan should be turned on with a demand for Humidity.
D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM Installer Setup Dry Contact Operation (setup step 70 - 73) Dry Contact Polarity (Setup Step 70) Open (Normally Open) - The dry contact Closed (Normally Closed) - The dry is open until the connected device closes contact is closed until the connected the circuit.
D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM Installer Setup Locking/Unlocking the Keypad To prevent unauthorized use of the thermostat, the front panel buttons may be disabled. To disable, or ‘lock’ the keypad, press and hold the MODE button. While holding the MODE button, press the UP and DOWN buttons together.
D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM Installer Setup Resetting the Thermostat to the Factory Default Settings (for default values see page 34) If, for any reason, you desire to return all the stored settings back to the factory default settings, follow the instructions below. WARNING: This will reset all Advanced Programming to the default settings.
D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM Technician Setup To enter Technician Setup, press and hold the SETUP button for 5 seconds. After all the icons appear, press MODE. The version numbers of the thermostat will appear in the scrolling text. Press MODE to advance to the next step.
D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM TroubleShooting SYMPTOM: The air conditioning does not attempt to turn on. CAUSE: The compressor timer lockout may prevent the air conditioner from turning on for a period of time. REMEDY: Consult the Owner's Manual in the Installer Setup section to defeat the Cycles Per Hour (page 22).
D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM Advanced Setup Table Df = Factory Default Setting -2200C-2 Description Step# Range Available Modes Heat/Cool/Auto/Off, Heat/Cool/ Heat/Cool/Off, Heat/Off, Auto/Off Cool/Off On, Off Backlight Off-7 levels of brightness Level 5 Backlight Level 0-1999 Current Service Filter Runtime Hours 0-1999 Current Service Filter Calendar Days 0-1999...
Page 32
D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM Advanced Setup Table Df = Factory Default Setting Range Step# Description Open Humidity Polarity Open,Closed Open Dehumidify Polarity Open,Closed Press Outdoor To Clear All Messages PAGE 28...
D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM Index fan, 1, 4 ,17 setpoint, 3, 5, 19 mode, 1, 5 to dehumidify, see outdoor, 1, 6 Dehumidify override, 1, 6 Condensate Drain Pan, reset filter, 1 service, 1 Cycles Per Hour, 20 Alerts setup, 1, 15, 19 see Runtime Accessory, 17 up (warmer), 1, 15...
Page 34
D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM Index on during heat, see indicator, 1 Dry Contact Electric Heat mode, 2, 5 operation, 22 icon, 4 program, 22 polarity, 22 stage heat, see runtime, see service pan, 22 Emergency Heat Run-Time override, 22 speed, see setpoint, 5, 21 Dehumidify Heat Pump...
Page 35
D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM Index Pan, Service Keypad Lockout, 23 Non-Programmable see Dry Contact Thermostat, ii Polarity, see Dry Contact Normally Open/Closed, dry contact, 22 dehum terminal, LCD, 1 Remote Sensor Language, 15 calibrate, 14, 24 control to, 20 Locked Indication, outdoor temperature, see Keypad see Outdoor...
Page 36
D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM Index viewing, humidification, 18 service filter, 18 UV lamp, 18 Warranty, 33 Technician Setup, 14, 25 Thermostat Sensor calibrate, 14, 24 Sensor Time Delay, outdoor, see Outdoor cycles per hour, remote, see Remote thermostat, see Thermostat Service filter, see Reset humidify, see...
Page 37
D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM Warranty Five-Year Warranty - This Product is warranted to be free from defects in material and workmanship. If it appears within five years from the date of original installation, whether or not actual use begins on that date, that the product does not meet this warranty, a new or remanufactured part, at the manufacturer’s sole option to replace any defective part, will be provided without charge for the part itself provided the defective part is returned to the distributor through a qualified servicing dealer.