Daikin TSTATD2200C-2 Owner's Manual And Installation Instructions

Daikin TSTATD2200C-2 Owner's Manual And Installation Instructions

Commercial non-programmable digital thermostat with humidity control, multi stage 2+2

Advertisement

D_TSTATD2200C-2_Manual_HR.pdf
Non-Programmable
Digital Thermostat
with Humidity Control • Multi Stage 2+2
for
Commercial Use
1
8/29/13
1:11 PM
TSTATD2200C-2
COMMERCIAL
Owner's
Manual
and
Installation
Instructions

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TSTATD2200C-2 and is the answer not in the manual?

Questions and answers

Summary of Contents for Daikin TSTATD2200C-2

  • Page 1 D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM TSTATD2200C-2 COMMERCIAL Non-Programmable Digital Thermostat with Humidity Control • Multi Stage 2+2 Owner's Manual Installation Instructions Commercial Use...
  • Page 2 (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Thermostat TSTATD2200C-2 Tested to Comply with FCC Standards FOR HOME OR OFFICE USE...
  • Page 3 D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM Glossary of Terms Auto-Changeover: A mode in which the thermostat will turn on the heating or cooling based on room temperature demand. Cool Setpoint: The warmest temperature that the space should rise to before cooling is turned on (without regard to deadband). Deadband: The number of degrees the thermostat will wait, once a setpoint has been reached, before energizing heating or cooling.
  • Page 4: Table Of Contents

    D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM Table of Contents Get to Know Your Thermostat Quick Start INSTALLATION INSTRUCTIONS Sample Wiring Diagrams Test Operation USER SETUP Backlight Operation Scrolling Display Options Thermostat Display Options Emergency Heat System Runtimes INSTALLER SETUP Advanced Setup Setpoint Limits Remote Sensor Operation Humidification &...
  • Page 5: Get To Know Your Thermostat

    D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM Get to Know Your Thermostat Front Panel Backlit LCD Display HUMIDITY MODE Scrolling Display PROGRAM HOLD TO SET Outdoor Heat or Cool OVERRIDE OVERRIDE Demand Indicator Red = Heat EMERGCY EMERGCY Green = Cool SET CLOCK HOLIDAY DISPLAY ACCESSORY SETUP RST FLTR...
  • Page 6 D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM Get to Know Your Thermostat Display Features Setup Step Stage Fan On Outdoor The scrolling display will be used to help you easily navigate the setup screens in the thermostat. Mode Indicators Selects the operational mode of the equipment. HEAT - Indicates the heating mode.
  • Page 7 D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM Get to Know Your Thermostat Display Features Setup Step Stage Fan On Outdoor Desired Set Temperature Indicates desired room temperature(s). 2nd Stage icon Indicates what stage of cooling or heating is currently energized. Setup Step icon Indicates the step number when the thermostat is in the setup mode.
  • Page 8 D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM Get to Know Your Thermostat Display Features Setup Step Stage Fan On Outdoor AuxHeat icon Indicates 2nd stage electric strip heat is being used when the thermostat is programmed for Heat Pump operation. Fan On icon Indicates constant, continuous fan operation.
  • Page 9: Quick Start

    D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM Quick Start During Setup and Programming: Press the UP or DOWN buttons to modify the selection. Press the MODE button to advance and confirm through the setup steps. Selecting the Heat or Cool Mode Select mode by pressing the MODE button. Heating Only - The HEAT setting indicates the temperature the room has to reach before the furnace will turn on to heat the room.
  • Page 10: Using The Override Button

    D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM Quick Start NOTE: Override may only be Using the Override Button used when the Dry Contact has forced the thermostat into the Unoccupied mode. Unoccupied Operation - During a Dry Contact forced unoccupied period pressing the OVERRIDE button will force the thermostat into the mode it was in before the Dry Contact forced it into the Unoccupied mode.
  • Page 11: Installation Instructions

    D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM Installation Instructions Remove & Replace the Old Thermostat To install the thermostat properly, please follow these step by step instructions. If you are unsure about any of these steps, call a qualified technician for assistance. Assemble tools: Flat blade screwdriver, wire cutters and wire strippers.
  • Page 12: Wire Connections

    D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM Installation Instructions Wire Connections Wire Connections If the terminal designations on your old thermostat do not match those on the new thermostat, refer to the chart below or the wiring diagrams that follow. Install on the Wire from the new thermostat old thermostat...
  • Page 13 D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM Installation Instructions The TSTATD2200C-2 Thermostat Backplate 1st stage heat/reversing valve W1/O/B Remote/Outdoor REMOTE/ sensor connections OUTDOOR 2nd stage heat circuit Dry Contact Humidifier control circuit connections CONTACT Dehumidifier control circuit DEHUM 2nd stage compressor 24 VAC common...
  • Page 14 D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM Installation Instructions Explanation of Thermostat Jumpers Jumpers are located on the back of the thermostat RV=O GAS/ELEC RV=O GAS/ELEC ELEC RV=B HEATPUMP ELEC RV=B HEATPUMP This jumper configures the thermostat to control a conventional GAS/ELEC GAS/ELEC gas/electric system or a heat pump.
  • Page 15: Sample Wiring Diagrams

    D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM Installation Instructions Sample Wiring Diagrams Conventional Heating and Cooling Systems 3 Wire, Heat Only 4 Wire, Cool Only Residential & Commercial 1 Stage Heating Residential & Commercial 1 Stage Cooling. with no Fan. 24VAC Power 24VAC Power 24VAC Common 24VAC Common 1st Stage Cool...
  • Page 16 D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM Installation Instructions Sample Wiring Diagrams Heat Pump Systems 5 Wire, 1 Stage Cooling, 1 Stage Heat 6 Wire, 1 Stage Cooling, 2 Stage Heat Residential & Commercial Heat Pump with Residential & Commercial Heat Pump with ‘O’...
  • Page 17 D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM Installation Instructions Sample Wiring Diagrams Humidification or Dehumidification Humidification System Dehumidification Terminal on Equipment DEHUM/ Dry Contact and Remote or Outdoor Sensor 10K Thermistor Remote or Outdoor Sensor Time Clock TSTATGAC-WS or TSTATGTAC-OS PAGE 13...
  • Page 18: Test Operation

    D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM Installation Instructions: Test Operation This thermostat has a diagnostic feature that enables testing of all outputs. This feature is contained in Technician Setup. To enter Technician Setup, press and hold the SETUP button for 5 seconds until all the icons appear.
  • Page 19: User Setup Backlight Operation

    D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM User Setup: Backlight Operation How to Change Settings in the Setup Screens To enter Advanced Setup, press the SETUP button, then press MODE. Use the UP or DOWN buttons to adjust the value of your selection. Press MODE to advance to the next setup step.
  • Page 20: Scrolling Display Options

    D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM User Setup: Scrolling Screen and Display Options Scrolling Display Method (Setup Step 19) This option allows the user to choose how the scrolling text is displayed. Options are: Scrolling Non-Scrolling Scroll Letters Slow Whole Words Slow Scroll Letters Fast Whole Words Fast Scroll Words Slow...
  • Page 21: Emergency Heat

    D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM User Setup Emergency Heat The Emergency Heat function is only available if your thermostat is set to control a Heat Pump. To initiate the Emergency Heat feature, Press and hold the EMERGCY HEAT button for 2 seconds. During Emergency Heat operation the thermostat will turn on the fan and auxiliary stages of heat when there is a demand for heat.
  • Page 22: System Runtimes

    D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM User Setup: System Runtimes These setup steps allow the user to monitor equipment runtimes and program service alerts. Runtime hours or days appear here in the display. System Runtimes (Setup Steps 6-17) Setup Step Press the SETUP button, then press MODE repeatedly until the desired setup step appears.
  • Page 23: Installer Setup

    D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM Installer Setup How to Change Settings in the Setup Screens To enter Advanced Setup, press the SETUP button, then press MODE. Use the UP or DOWN buttons to adjust the value of your selection. Press MODE to advance to the next setup step.
  • Page 24: Remote Sensor Operation

    D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM Installer Setup Cycles Per Hour (Setup Step 23) The Cycles Per Hour setting may limit the number of times per hour your HVAC unit may energize. For example, at a setting of 6 cycles per hour the HVAC unit will only be allowed to energize once every 10 minutes.
  • Page 25: Humidification & Dehumidification

    D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM Installer Setup Humidity and Dehumidity (Setup Steps 40-44, 75-76) Humidity Only With Heat (Setup Step 40) - When this step is set to ON, Humidity will not run without a demand for Heat. Fan With Humidity Demand (Setup Step 41) - Specifies if the fan should be turned on with a demand for Humidity.
  • Page 26: Dry Contact Operation

    D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM Installer Setup Dry Contact Operation (setup step 70 - 73) Dry Contact Polarity (Setup Step 70) Open (Normally Open) - The dry contact Closed (Normally Closed) - The dry is open until the connected device closes contact is closed until the connected the circuit.
  • Page 27: Locking And Unlocking The Keypad

    D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM Installer Setup Locking/Unlocking the Keypad To prevent unauthorized use of the thermostat, the front panel buttons may be disabled. To disable, or ‘lock’ the keypad, press and hold the MODE button. While holding the MODE button, press the UP and DOWN buttons together.
  • Page 28: Factory Defaults

    D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM Installer Setup Resetting the Thermostat to the Factory Default Settings (for default values see page 34) If, for any reason, you desire to return all the stored settings back to the factory default settings, follow the instructions below. WARNING: This will reset all Advanced Programming to the default settings.
  • Page 29: Technician Setup

    D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM Technician Setup To enter Technician Setup, press and hold the SETUP button for 5 seconds. After all the icons appear, press MODE. The version numbers of the thermostat will appear in the scrolling text. Press MODE to advance to the next step.
  • Page 30: Troubleshooting

    D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM TroubleShooting SYMPTOM: The air conditioning does not attempt to turn on. CAUSE: The compressor timer lockout may prevent the air conditioner from turning on for a period of time. REMEDY: Consult the Owner's Manual in the Installer Setup section to defeat the Cycles Per Hour (page 22).
  • Page 31: Advanced Setup Table

    D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM Advanced Setup Table Df = Factory Default Setting -2200C-2 Description Step# Range Available Modes Heat/Cool/Auto/Off, Heat/Cool/ Heat/Cool/Off, Heat/Off, Auto/Off Cool/Off On, Off Backlight Off-7 levels of brightness Level 5 Backlight Level 0-1999 Current Service Filter Runtime Hours 0-1999 Current Service Filter Calendar Days 0-1999...
  • Page 32 D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM Advanced Setup Table Df = Factory Default Setting Range Step# Description Open Humidity Polarity Open,Closed Open Dehumidify Polarity Open,Closed Press Outdoor To Clear All Messages PAGE 28...
  • Page 33: Index

    D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM Index fan, 1, 4 ,17 setpoint, 3, 5, 19 mode, 1, 5 to dehumidify, see outdoor, 1, 6 Dehumidify override, 1, 6 Condensate Drain Pan, reset filter, 1 service, 1 Cycles Per Hour, 20 Alerts setup, 1, 15, 19 see Runtime Accessory, 17 up (warmer), 1, 15...
  • Page 34 D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM Index on during heat, see indicator, 1 Dry Contact Electric Heat mode, 2, 5 operation, 22 icon, 4 program, 22 polarity, 22 stage heat, see runtime, see service pan, 22 Emergency Heat Run-Time override, 22 speed, see setpoint, 5, 21 Dehumidify Heat Pump...
  • Page 35 D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM Index Pan, Service Keypad Lockout, 23 Non-Programmable see Dry Contact Thermostat, ii Polarity, see Dry Contact Normally Open/Closed, dry contact, 22 dehum terminal, LCD, 1 Remote Sensor Language, 15 calibrate, 14, 24 control to, 20 Locked Indication, outdoor temperature, see Keypad see Outdoor...
  • Page 36 D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM Index viewing, humidification, 18 service filter, 18 UV lamp, 18 Warranty, 33 Technician Setup, 14, 25 Thermostat Sensor calibrate, 14, 24 Sensor Time Delay, outdoor, see Outdoor cycles per hour, remote, see Remote thermostat, see Thermostat Service filter, see Reset humidify, see...
  • Page 37 D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM Warranty Five-Year Warranty - This Product is warranted to be free from defects in material and workmanship. If it appears within five years from the date of original installation, whether or not actual use begins on that date, that the product does not meet this warranty, a new or remanufactured part, at the manufacturer’s sole option to replace any defective part, will be provided without charge for the part itself provided the defective part is returned to the distributor through a qualified servicing dealer.
  • Page 38 D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM Notes:...
  • Page 39 D_TSTATD2200C-2_Manual_HR.pdf 8/29/13 1:11 PM Notes:...
  • Page 40 D_TSTATD2200C-2 Manual_p44.pdf 9/5/13 12:02 PM Notes: Printed on recycled paper. P/N 88-981 Rev. 1...

Table of Contents