Nº | Meaning | Action |
1 | On/Off | On/off for the zone |
2 | Zone settings | Access to zone parameters |
3 | User settings | Access to user settings menu |
4 | Time schedules | Access to time schedules menu |
5 | Local ventilation | Enable / disable the local ventilation |
6 | Zone demand | Displayed when the zone is calling for demand |
7 | Set-point temperature | Change the set-point temperature |
8 | Room temperature and humidity percentage | Displays the room temperature and the relative humidity in the zone |
9 | Current zone | Access to remote zone control |
10 | Operation mode | Access to operation mode menu (Main only) |
11 | User mode | Access to User mode menu (Main only) |
12 | Airflow control | Access to Airflow control menu (Main only) |
Nº | Meaning | Action |
1 | Date and time | Displays the current date and time |
2 | Current zone | Displays the name of the current zone |
3 | Room temperature | Displays the room temperature |
4 | Humidity percentage | Displays the percentage of room humidity |
5 | On/Off | On/off for the zone |
6 | Operation mode | Displays the current operation mode |
Note: Do not connect the "-" pole to the "+" terminal. It may damage the device.
Meaning | |
Error 1 | Communication error with the main controller |
Error 5 | Temperature sensor is open |
Error 6 | Temperature sensor is short circuited |
Error 8 | Wireless Lite thermostat not found |
Error 9 | Communications error between the Daikin Interface Board and the system |
Error 10 | Communication error between the DZK BACnet Interface and the system |
Error 11 | Communication error between the Daikin Interface Board and the Daikin indoor unit |
Note: Refer to the DZK installation manual for troubleshooting steps.
Color graphic interface with capacitive screen for controlling zones in DZK systems. Powered by Main Control Board. Finished in steel and glass.
Functionalities:
Phone: (855) 770-5678 | http://www.daikinac.com
Power supply and consumption | |
Type of power supply | Vdc |
V max | 12 V supplied from the Main Control Board |
I max | 145 mA |
Stand-by consumption | 0.876 W |
Connection and communications | |
Shielded twisted pair | AWG 20 – 4 wired |
Maximum wiring length (Control board to thermostat) | 130 ft (40 m) |
Operating temperatures | |
Storage | -4 to 158ºF (-20 to 70 ºC) |
Operation | 32 to 122ºF (0 to 50ºC) |
Operating humidity range | 5 to 90% (non-condensing) |
Set-point temperature range | 59 to 86ºF (15 to 30ºC) |
Reading accuracy | ±1ºF (±0.5 ºC) |
Display accuracy | ±1ºF (±0.5 ºC) |
Relative humidity | ±4% |
Mechanical aspects | |
Assembly | Surface through support |
Protection class | IP 20 |
Type of probe | Airzone_NTC_10K |
Weight (Mass) | 0.44 lb (198 g) |
Dimensions (WxHxD) | 3.62x3.62x0.62 inch (92x 92x15.85 mm) |
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.