Table 3-5 Default Settings For Bop Operation - Siemens MICROMASTER 411 Operating Instructions Manual

Siemens welding system - ac/dc welding inverter user manual
Hide thumbs Also See for MICROMASTER 411:
Table of Contents

Advertisement

3 Commissioning
3.3.4.1
Commissioning with the Basic Operator Panel (BOP)
showing parameter numbers and values, alarm and fault messages and setpoints
and actual values. Parameter sets cannot be saved via the BOP.
Control functions for the inverter (ON/OFF,
works settings. In order to specify this command via the BOP, P0700 = 1 must be
set.
If the BOP connection is removed during normal running the drives is stopped and
the motor coasts to standstill.
Table 3-5 shows the factory default settings for operation via the BOP.
Table 3-5
Parameter
P0100
P0307
P0310
P0311
P1082
50
The Basic Operator Panel (BOP), which is available as an
optional accessory, provides the user with access to the
inverter parameters and enables you to customize the
settings of your COMBIMASTER 411 & MICROMASTER
411. The BOP is mounted in an Operator Panel Mounting
Kit and connected to the COMBIMASTER 411 &
MICROMASTER 411 via the serial interface (see Figure
3-9). The BOP can be used to configure several
COMBIMASTER 411 & MICROMASTER 411 Inverters.
The BOP features a five-digit, seven-segment display for
Default Settings for BOP Operation
Meaning
Operating Mode Europe/US
Power (rated motor)
Motor frequency rating
Motor speed rating
Maximum Motor Frequency
MICROMASTER 411 & COMBIMASTER 411
,
, reverse) are not active in the
Default Europe (North America)
50 Hz, kW (60 Hz, hp)
kW (Hp)
50 Hz (60 Hz)
1395 (1680) rpm [depending on variant]]
50 Hz (60 Hz)
6SE6400-5CA00-0BP0
Issue 03/01
Operating Instructions

Advertisement

Table of Contents
loading

This manual is also suitable for:

Combimaster 411

Table of Contents