3 Commissioning
Table 3-1
Digital Input 1
Digital Input 2
Digital Input 3
Digital Input 4
Digital Input 5
Digital Input 6
Digital Input 7
Digital Input 8
3.2.3
Basic operation with SDP
With the SDP fitted, the following is possible:
Start and stopping the motor (DIN1 via external switch)
Reversing the motor (DIN2 via external switch)
Fault Reset (DIN3 via external switch)
Controlling the speed of the motor is accomplished by connecting the analog inputs
as shown in the Figure 3-4.
OFF = Voltage 0 - 10 V
ON
= 0 - 20 mA
OFF = Voltage 0 - 10 V
ON
= 0 - 20 mA
Analogue
Output
0 - 20 mA
(500
)
Figure 3-4
36
Default settings for operation using the Status Display Panel
Terminals
Parameter
5
P0701 = '1'
6
P0702 = '12'
7
P0703 = '9'
8
P0704 = '15'
16
P0705 = '15'
17
P0706 = '15'
Via AIN1
P0707 = '0'
Via AIN2
P0708 = '0'
AIN2
AIN1
Basic operation with SDP
http://nicontrols.com
International English
Default Operation
ON right
Reverse
Fault Acknowledge
Fixed Frequency
Fixed Frequency
Fixed Frequency
Inactive
Inactive
P+
N-
ACK
MICROMASTER 440
Operating instructions
6SE6400-5CA00-0BP0