Issue 03/01
10.12

Shock and Vibration

The inverter has been tested for compliance with the following standards.
10.12.1
Vibration Stress during Operation (Single Sine Sweep)
Required Standards:
Test standards:
Case Size B:
Case Size C:
10.12.2
Shock Stress during Operation (Half Sine Shock)
Required Standards:
Test standards:
Case Size B:
Case Size C:
10.12.3
Vibration and Shock stress during Transport
Required Standards:
Test standards:
Class 2M2:
Class 2M1:
The inverter meets class 2M2 for Vibration stress and 2M1 for shock stress in
product packaging.
MICROMASTER 411 & COMBIMASTER 411
6SE6400-5CA00-0BP0
EN 60721-3-3 class 3M6 and 3M8
EN60068-2-6, test Fc
Class 3M6: 10-58 Hz/ 0.15 mm, 58-200 Hz/ 2g
Class 3M6: 10-58 Hz/ 0.15 mm, 58-200 Hz/ 2g
EN 60721-3-3
EN 60068-2-27, test Ea
Peak acceleration 5g - duration of shock 30 ms
Peak acceleration 5g - duration of shock 30 ms
EN 60721-3-3
EN 60068-2-27, Test Ea
5-9 Hz/ 3.5 mm, 9-200 Hz/ 1g
Peak acceleration 15g - duration of shock 11 ms.