Fire Tone-Out Introduction; Setting Tone-Out Standby; Setting Up Tone-Out - Uniden Trunk Tracker IV BCD996T User Manual

Scanning radio
Table of Contents

Advertisement

On — the scanner checks the weather channels every 5 seconds for a 1050 Hz weather alert signal. Press the Scroll Control to
select.
Off — the scanner does not check the weather channels. This is the default setting. Press
Notes:
You can also turn this option on and off by pressing the front-panel WX key.
When you turn on this option, you will notice a break in the audio every 5 seconds as the scanner checks for the weather
alert signal.

Fire Tone-Out Introduction

Your scanner can be set to respond to fire tone-outs, a system comprised of standardized two-tone sequential paging, short one-
tone paging, and long group tone paging. You can save up to 10 settings. When you select a setting in standby mode, the scanner
also monitors for any other setting that uses the same transmit frequency, modulation, and attenuation settings.
You need tone-out setup information from the agency you wish to monitor. Check with your local agency or on-line resources as
Uniden America Corporation has no information regarding local tone-out systems.

Setting Tone-Out Standby

[MENU]
Tone-Out for...
Tone-Out Standby
Turn the Scroll Control
and attenuation setting as the one you select, are also monitored.
In standby mode, the display cycles through all monitored tone-out settings. Regardless of the current display, the scanner always
alerts on any received tone-out that matches a stored setting.
If you press [HOLD/RESUME] while in standby mode, the scanner temporarily exits the mode and you hear all transmissions on that
frequency. No alerts sound, even if a tone-out matches one you have stored. Press [HOLD/RESUME] again to return to standby
mode.

Setting Up Tone-Out

[MENU]
Tone-Out for...
Tone-Out Setup
Scroll to select the tone-out (1 - 10) you want to program, then press
press
to select and modify the selected settings:
Edit Name — Sets the name for the selected tone-out setting.
Set Frequency — Sets the tone-out's RF frequency parameters. Then select:
Edit Frequency — Enter the desired frequency that the scanner should monitor for the tone-out.
Set Modulation — Set the modulation type for the paging signal. Next choose the modulation setting:
Auto —The scanner uses the default modulation for the frequency band. If the default modulation is AM, WFM,
or FMB, the modulation operates as FM.
FM — The scanner uses FM for the frequency band. This is the default setting.
NFM — The scanner uses NFM modulation.
Set Attenuation — Turn the Scroll Control to select On or Off.
to select which of the ten tone-outs to monitor. All tone-outs that have the same frequency, modulation,
Then you can scroll to any of the following settings and
.
60
to select.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents