km – The scanner uses kilometers.
Setting the Serial Port Speed
[MENU]
Settings
Use this setting to control the data rate used for the front and back panel serial ports. You typically set the front port to match the
speed used to communicate with your PC (default 115000 bps) and the back port to the speed used to communicate with an
attached GPS (default 4800 bps). Note that the back port is male. You may need a gender changer and a null modem adapter to use
a typical DB9 serial cable from the rear port.
For Serial Port Speed (Baud Rate), you may select from
4800 bps
9600 bps
19200 bps
38400 bps
57600 bps
112500 bps
OFF
Displaying Scanner Information
Viewing Memory Used
[MENU]
Settings
See Scanner Info
% Memory Used
A bar showing the percent of memory used appears as well as a percentile to the right of the screen.
Press any key to return to the previous menu, then press any key to exit the menu.
Viewing the Firmware Version and Electronic Serial Number
[MENU]
Settings
See Scanner Info
Press any key to return to the previous menu, then press any key.
Initializing the Scanner's Memory
Warning: This clears data you have entered. You cannot restore user programmed data that has been deleted. You can, at a last
step, restore only the original factory data.
1. To initialize the scanner's memory, turn off the scanner.
2. While pressing [2], [9], and [HOLD] at the same time, turn on power.
At that point anything you have programmed is gone.
You are given a last opportunity to keep the factory programmed data when you see the question:
:Restore Preprogram List? Yes="E"/"No= "."
If you do not say Yes, the scanner is totally empty.
Connecting Your Scanner to a Personal Computer
Set Serial Port
Firmware Version
Set Baud Rate
26