34 Start-up
No.
Name/Value
28
FBA Par table
ver
0..0xFFFF
29
FBA Drive type
code
0...65535
30
FBA Mapping
file ver
0...65535
31
D2FBA comm
status
0 = Idle
1 = Exec.init
2 = Time out
3 = Conf.err
4 = Off-line
5 = On-line
Description
Displays the parameter table
revision of the fieldbus adapter
module mapping file stored in the
memory of the drive.
In format xyz, where
x = major revision number
y = minor revision number
z = correction number
This parameter is read-only.
Parameter table revision
Displays the drive type code of the
fieldbus adapter module mapping file
stored in the memory of the drive.
This parameter is read-only.
Drive type code of the fieldbus adapter
module mapping file
Displays the fieldbus adapter module
mapping file revision stored in the
memory of the drive in decimal format.
This parameter is read-only.
Mapping file revision
Displays the status of the fieldbus
adapter module communication.
This parameter is read-only.
Note: The value names may vary by
drive.
Adapter is not configured.
Adapter is initializing.
A timeout has occurred in the
communication between the adapter
and the drive.
Adapter configuration error
Adapter is off-line.
Adapter is on-line.
Default
0 hex
0
0
0 = Idle