4. Commissioning
Inputs
1. Number of 4−input modules
2. Number of 8−input modules
3. Number of 16−input modules
4. Number of other inputs, e. g. multi I/O module
5. The 4 status bits are assigned internally automatically by the valve terminal.
Total number of inputs to be configured
Outputs
6. Number of single−solenoid sub−bases MIDI/MAXI
7. Number of double−solenoid sub−bases MIDI/MAXI
8. Number of type 04−B single−solenoid sub−bases
9. Number of type 04−B double−solenoid sub−bases
*)
Note the possible address reservations with type 04−B
10.Check to see if the sum of 6. 9.
is divisible by four without remainder.
This check is necessary because of the 4−bit−orientated
internal addressing of the terminal.
The following distinction is made:
a) if divisible by four without remainder: continue with point 11.
b) If not: round up to the next half byte (+1...3).
11.Number of 4−output electric modules
12.Number of other outputs, e. g. multi I/O module
Total number of outputs to be configured
Festo P.BE−VIFB5−03−EN en 0503e
Calculating the number of inputs/outputs
*)
*)
Intermediate sum 6. 9.
________ x 4
+
________ x 8
+
________ x 16
+
+
=
________ x 2
+
________ x 4
+
________ x 1
+
________ x 2
=
+
+
________ x 4
+
=
Σ
E
Σ
E
Σ
E
Σ
E
4 E
Σ
E
Σ
A
Σ
A
Σ
A
Σ
A
Σ
A
2 A
Σ
A
Σ
A
Σ
A
4−5