5. Diagnosis and error treatment
Festo P.BE−VIFB5−03−EN en 0503e
1
15
= valve terminal not connected
D
2
Device type 0,2 or 4D
0
= Binary entry (terminal only with inputs)
D
2D = Binary output (terminal only with outputs)
4D = Binary inputs/outputs (terminal with inputs/out
puts)
3
Group no. (= set field bus address, decimal)
4
1
= internal module error (terminal V
D
4
= overload or short circuit (terminal short circuit/
D
overload)
5
Channel no. in conjunction with the Festo valve ter
minals types 03/04−B is always 0.
Fig. 5/18: Example 07KR91: Error recognition of the Festo
valve terminals
Example 2 coupler 07CS61
The diagnostic information of the terminals is entered in the
following system flags:
Line 1: MW 4104.02...10
Line 2: MW 4105.10..15
Line 3: MW 4107.02...10
Line 4: MW 4108.10..15
Example for line 1:
(see next page)
, V
, V
)
VAL
SEN
OUT
5−25