g a s s u P P l Y & i n s t a l l a t i o n
Warning
To prevent SERIOUS INjURY or DEATH from
fire or explosion:
Only connect the type of gas indicated on the
identification nameplate. Your gas Combitherm
is equipped to operate using only the fuel type
specified on the identification name plate. Should
conversion from natural gas to propane or from
propane to natural gas be desired, conversion parts
must be ordered from Alto-Shaam. Conversions must
Alto-Shaam authorized service
be peformed by an
provider only.
always ensure the oven's nameplate
reflects the intended fuel type for your oven.
Residential gas connections and hard-piped gas
connections DO NOT meet NSF certifications and
should NEVER be used with your Combitherm oven.
Please refer to model specifications for rated thermal
loads and connected pressure requirements.
Natural
GR
CY
ES/FR/GB/IE/CH
AT
BE
DE
NL
Butane/Propane Mixture Cat
GR
CY
ES/FR/GB/IE/CH
AT
BE
DE
NL
AUS/NZ
AUS/NZ
Japan
Japan
COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 43.
installation
®
Cat
Gas Type
II2H3B/P
2H-G20-20mbar
II2H3B/P
2H-G20-20mbar
II2H3P
2H-G20-20mbar
II2H3B/P
2H-G20-20mbar
II2E(S)3B/P 2H-G20-20mbar
II2ELL3B/P 2E-G20/G25-20mbar
II2L3B/P
2L-G25-25mbar
Gas Type
II2H3B/P
3B/P-G30/G31-30mbar
II2H3B/P
3B/P-G30/G31-30mbar
II2H3P
3P-G31-30mbar
II2H3B/P
3B/P-G30/G31-50mbar
II2E(S)3P
3P-G31-30mbar
II2ELL3B/P 3B/P-G30/G31-50mbar
II2L3B/P
3B/P-G30/G31-30mbar
NGN 1,0kPa
LPG-X Propane 2.75 kPa
Natural Gas 13A 1.96 kPa
LPG - Propane 2.8 kPa
W a r n i n g
To prevent SERIOUS PERSONAL
INJURY, installation of this appliance
must conform to local, state, and
national codes; the current edition
of the American National Standard
Z223.1, National Fuel Gas Code, and
all local municipal building codes.
In Canada, installation must be in
accordance with Standard CAN/CSA
B 149.1 and Installation Codes - Gas
Burning Appliances, and local codes.
NOTICE: Connection components not supplied by
Alto-Shaam must comply with the
regulations in force of the country of use.
sediment traP
required:
Where a sediment trap is not
incorporated as part of the appliance,
a sediment trap shall be installed
downstream of the appliance shutoff
valve as close to the inlet of the
appliance as practical at the time of
appliance installation. The sediment
trap shall be either a tee fitting with
a capped nipple in the bottom outlet,
as illustrated below or another device
recognized as an effective sediment trap.
To
equipment
inlet
Nipple
Cap
Gas supply inlet
Tee fitting
80mm
minimum