35-11/16" (906mm)
26-3/16" (665mm)
WATER REQUIREMENTS
TWO (2) COLD WATER INLETS - DRINKING QUALITY
ONE (1) TREATED WATER INLET:
ONE (1) UNTREATED WATER INLET: 3/4" NPT*
LINE PRESSURE: 30 psi minimum dynamic and 90 psi maximum static (2.1 to 6.3 bar)
WATER DRAIN: 1-1/2" (40mm)
CONNECTION WITH A
MATERIALS MUST WITHSTAND TEMPERATURES UP TO
CLEARANCE REQUIREMENTS
LEFT: 0" (0mm)
RIGHT: 0" (0mm)
NON-COMBUSTIBLE SURFACES
TOP: 20" (508mm)
FOR AIR MOVEMENT
4" (102mm)
BACK:
4-5/16" (109mm)
OPTIONAL PLUMBING KIT
INSTALLATION REQUIREMENTS
• Oven must be installed level.
• Water supply shut-off valve and back-flow preventer when required by local code.
GAS REQUIREMENTS
(GAS TYPE MUST BE SPECIFIED ON ORDER)
RATED THERMAL LOAD
NORTH AMERICA
Natural Gas/Propane
Gross Heating Value (HHV)
80,000 Btu / hr
ELECTRICAL - CTP10-10G
(DEDICATED CIRCUIT REQUIRED) DO NOT CONNECT TO A G.F.I. OUTLET
VOLTAGE
PH
HZ
120
1
60


208 – 240
1
50/60
¦


208 – 240
3
50/60

380 – 415
3
50/60

NORTH AMERICA VOLTAGE CHOICE

WEIGHT
NET
625 lbs
283 kg
EST
SHIP
675 lbs*
306 kg*
SHIP DIMENSIONS
(L x W x H) 56" x 45" x 65"*
(1422 x 1143 x 1651mm)*
*
.
DOMESTIC GROUND SHIPPING INFORMATION
CONTACT FACTORY FOR EXPORT WEIGHT AND DIMENSIONS
COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 16.
INTERIOR DIMENSIONS: 800mm x 411mm x 712mm
EXTERIOR DIMENSIONS: 1173mm x 907mm x 995mm
6.10 OVER 10.10: 1850mm x 907mm x 995mm
10.10 ON 28" STAND: 2013mm x 907mm x 995mm
41-7/16" (1053mm)
B
D
A
E
28-3/4" (730mm)
1-11/16" (42mm)
IP X5
3/4" NPT*
* Can manifold off of
one 3/4" line
VERTICAL VENT TO EXTEND ABOVE THE EXHAUST VENT
200°F (93°C).
18" (457mm)
RECOMMENDED SERVICE ACCESS
2" (51mm)
DOOR SWING OR
COMBUSTIBLE SURFACES
BOTTOM: 5-1/8" (130mm)
FOR LEGS, AIR INTAKE
• Hood installation is required.
INTERNATIONAL
G20, G25, G31
Net Heating Value (LHV)
Minimum: 5.5" W.C. dynamic
21.0 kW
CONNECTION
AWG
AMPS
no cord, no plug
14
L1, N, G
6.8
14
L1, L2/N, G
4.8 – 4.2
14
L1, L2, L3, G
4.8 – 4.2
14
L1, L2, L3, N, G
4.6 – 4.2
INTERNATIONAL VOLTAGE CHOICE

PAN CAPACITY
FULL–SIZE:
GN 1/1:
**HALF–SIZE SHEET:
PRODUCT CAPACITY
PRODUCT MAXIMUM
VOLUME MAXIMUM
A= UNTREATED WATER
B= TREATED WATER
C= ELECTRICAL
D= GAS
E= WATER DRAIN
B
D
A
E
C
3-5/16" (84mm)
4-5/16" (109mm)
6-13/15" (171mm)
6-15/16" (176mm)
DIMENSIONS: H x W x D
EXTERIOR:
45-11/16" x 35-11/16" x 41-7/16" (1160mm x 906mm x 1053mm)
EXTERIOR WITH RECESSED DOOR:
45-11/16" x 40-11/16" x 41-7/16" (1160mm x 1033mm x 1053mm)
INTERIOR:
31-1/2" x 16-1/4" x 28-1/16" (800mm x 411mm x 712mm)
WATER QUALITY STANDARDS
It is the sole responsibility of the owner/operator/purchaser of this equipment
to verify that the incoming water supply is comprehensively tested and if
required, a means of "water treatment" provided that would meet compliance
requirements with the published water quality standards shown below.
Non-compliance with these minimum standards will potentially damage this
.
equipment and/or components and void the original equipment manufacturer's
warranty. Alto-Shaam recommends using OptiPure
products to properly treat your water.
Total Dissolved Solids (tds)
HOOK-UP: 3/4" NPT
CONNECTED PRESSURE
NORTH AMERICA
Natural Gas
Minimum: 9" W.C. dynamic
Maximum: 14" W.C. static
Maximum: 14" W.C. static
CONNECTION
BREAKER
kW
no cord, no plug
20
.84
15
1.0
15
1.0
L1, L2, L3, G
15
1.0
L1, L2, L3, N, G
ELECTRICAL SERVICE CHARGE APPLIES
¦
STANDARD MODEL
20" x 12" x 2-1/2"
Eleven (11)
530 x 325 x 65mm
Eleven (11)
18" x 13" x 1"
Eleven (11)
.
**
ON WIRE SHELVES ONLY
CTP10-10G
Gas boilEr
6-11/16" (168mm)
4-1/4" (108mm)
A, B, D, E
C - at bottom
of oven
39-1/4" (996mm)
®
[www.optipurewater.com]
Contaminant
Inlet Water Requirements
Free Chlorine
Less than 0.1 ppm (mg/L)
Hardness
30-70 ppm
Chloride
Less than 30 ppm (mg/L)
pH
7.0 to 8.5
Silica
Less than 12 ppm (mg/L)
50-125 ppm
Propane
WITH COMBISMOKER
OPTION
®
AMPS
BREAKER
L1, N, G
12.0
L1, L2/N, G
7.3 – 7.1
7.3 – 7.1
7.2 – 7.1
WITH COMBISMOKER
Eleven (11)
120 lb (54 kg)
75 quarts (95 liters)
.
ADDITIONAL WIRE SHELVES REQUIRED FOR MAXIMUM CAPACITY
10.10 GAS
-
frEE
INTERNATIONAL
G20
20mbar
G25
20mbar
G31
30mbar
kW
20
1.46
15
1.5 – 1.7
15
1.5 – 1.7
15
1.6 – 1.7
®
OPTION
Ten (10)
Ten (10)

Advertisement