e l e c t r i c a l c o n n e c t i o n f o r e l e c t r i c m o d e l s
1. An electrical wiring diagram is located behind
the control panel on the left side of the oven. This
appliance must be branch circuit protected with
proper ampacities, in accordance with the wiring
diagram.
do not connect to a g.f.I. outlet.
2.
Random and/or nuisance breaker trips could
occur. Consult with the NEC codes for specific
load values.
3. Wire size for the main incoming power to the
unit must match the minimum size listed in the
specifications applicable to the specific oven
model. For supply connections, locate the wire
size posted on the label located on the electrical
control box cover, behind the service panel.
4. Before operating the oven, check all cable
connections and electrical terminal connections in
the electrical connection area for tightness since
connections can loosen during transport.
Hard wired models:
Hard wired models must be equipped with a country
certified external allpole disconnection switch with
sufficient contact separation.
If a power cord is used for the connection of the product an
oil resistant cord like H05RN or H07RN or equivalent must
be used.
COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 40.
i n s t a l l a t i o n
NOTICE: check motor rotation on the
380-415V:
combitherm® ct classic ctc model
line. arrows on the motor housing
indicate proper rotation.
after both water and electrical
connections have been completed on all
combitherm model types, operate the
oven in any cooking mode for a period
of 15 minutes. Recheck the main power
connections at the terminal block, cable
connections, and electrical terminal
connections to make certain they remain
tight.
For CE approved units: To prevent an electrical
shock hazard between the appliance and other
appliances or metal parts in close vicinity,
an equalization-bonding stud is provided. An
equalization bonding lead must be connected to
this stud and the other appliances/metal parts
to provide sufficient protection against potential
difference. The terminal is marked with
the following symbol.