Specifications, Ctp20-10E - COMBITHERM CT PROformance Series Installation Manual

Table of Contents

Advertisement

35-11/16" (906mm)
19-1/8"
1" (24mm)
(486mm)
33-13/16" (858mm)
WATER REQUIREMENTS
TWO (2) COLD WATER INLETS - DRINKING QUALITY
ONE (1) TREATED WATER INLET:
3/4" NPT*
ONE (1) UNTREATED WATER INLET: 3/4" NPT*
LINE PRESSURE: 30 psi minimum dynamic and 90 psi maximum static (2.1 to 6.3 bar)
WATER DRAIN: 1-1/2" (40mm)
CONNECTION WITH A
MATERIALS MUST WITHSTAND TEMPERATURES UP TO
CLEARANCE REQUIREMENTS
LEFT: 0" (0mm)
RIGHT: 0" (0mm)
NON-COMBUSTIBLE SURFACES
TOP: 20" (508mm)
FOR AIR MOVEMENT
4" (102mm)
BACK:
4-5/16" (109mm)
OPTIONAL PLUMBING KIT
INSTALLATION REQUIREMENTS
• Oven must be installed level.
• Water supply shut-off valve and back-flow preventer when required by local code.
ELECTRICAL - CTP20-10E
(NO CORD, NO PLUG, DEDICATED CIRCUIT REQUIRED) DO NOT CONNECT TO A G.F.I. OUTLET
VOLTAGE
PH
HZ
AWG
CONNECTION
208 – 240
3
50/60 1 – 1/0
L1, L2, L3, G
380 – 415
3
50/60 4 – 3
L1, L2, L3, N, G
440 – 480
3*
50/60 6 – 4
L1, L2, L3, G
*ELECTRICAL SERVICE CHARGE APPLIES
WEIGHT
SHIP DIMENSIONS
NET
905 lbs est 411 kg
(L x W x H)
SHIP
955 lbs*
433 kg*
(1422 x 1143 x 2210mm)*
*
.
DOMESTIC GROUND SHIPPING INFORMATION
CONTACT FACTORY FOR EXPORT
.
WEIGHT AND DIMENSIONS
COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 26.
ALL DIMS LISTED AS H x W x D
INTERIOR DIMENSIONS: 1535mm X 411mm X 712mm
EXTERIOR DIMENSIONS: 2012mm X 907mm X 995mm
42-1/4" (1072mm)
B
A
D
28-13/16" (732mm)
1-15/16" (49mm)
1-11/16" (42mm)
IP X5
* Can manifold off of
one 3/4" line
VERTICAL VENT TO EXTEND ABOVE THE EXHAUST VENT
200°F (93°C).
18" (457mm)
RECOMMENDED SERVICE ACCESS
2" (51mm)
DOOR SWING OR
COMBUSTIBLE SURFACES
BOTTOM: 5-1/8" (130mm)
FOR LEGS, AIR INTAKE
• Hood installation is required.
ECO
STANDARD
AMPS
kW
BREAKER
AMPS
78.8 – 90.9 28.4 – 37.8
80 – 90
98.8 – 114 33.2 – 44.2 100 – 125 81.3 – 93.8 28.9 – 38.5 90 – 100 101.3 – 116.9 33.7 – 44.9 110 – 125
48.2 – 52.5 32.3 – 37.8
63
60.5 – 65.8 37.1 – 44.2
41.7 – 45.5 32.4 – 37.8
50
52.2 – 57
**NO-COST OPTION ON ELECTRIC MODELS
PAN CAPACITY
56" x 45" x 87"*
FULL–SIZE:
**HALF-SIZE SHEET:
805603
CTP20-10E
B
A
D
C
3-1/4" (81mm)
4-3/16" (106mm)
5" (126mm)
7" (178mm)
DIMENSIONS: H x W x D
EXTERIOR:
79-1/4" x 35-11/16" x 42-1/4" (2012mm x 906mm x 1072mm)
EXTERIOR WITH RECESSED DOOR:
79-1/4" x 40-11/16" x 42-1/4" (2012mm x 1033mm x 1072mm)
INTERIOR:
60-7/16" x 16-1/4" x 28-1/16" (1535mm x 411mm x 712mm)
WATER QUALITY STANDARDS
It is the sole responsibility of the owner/operator/purchaser of this equipment
to verify that the incoming water supply is comprehensively tested and if
required, a means of "water treatment" provided that would meet compliance
requirements with the published water quality standards shown below.
Non-compliance with these minimum standards will potentially damage this
.
equipment and/or components and void the original equipment manufacturer's
warranty. Alto-Shaam recommends using OptiPure
products to properly treat your water.
Contaminant
Free Chlorine
Total Dissolved Solids (tds)
**PROpower™
OPTION
kW
BREAKER
AMPS
63 – 80
50.9 – 55.4 32.8 – 38.5
37.2 – 44.2
60
43 – 46.9 32.9 – 38.5
20" x 12" x 2-1/2"
Twenty (20)
GN 1/1:
530 x 325 x 65mm
Twenty (20)
18" x 26" x 1"
Twenty (20)
20.10 ELECTRIC
ElEctric boilEr
ElEctric boilEr
6-11/16" (168mm)
4-1/4" (108mm)
A, B, D
C - at bottom
of oven
39-11/16" (1008mm)
A= UNTREATED WATER
B= TREATED WATER
C= ELECTRICAL
D= WATER DRAIN
®
[www.optipurewater.com]
Inlet Water Requirements
Less than 0.1 ppm (mg/L)
Hardness
30-70 ppm
Chloride
Less than 30 ppm (mg/L)
pH
7.0 to 8.5
Silica
Less than 12 ppm (mg/L)
50-125 ppm
®
WITH COMBISMOKER
OPTION
ECO
**PROpower™
STANDARD
kW
BREAKER
AMPS
63
63.1 – 68.7 37.7 – 44.9
50
53.6 – 58.5 37.8 – 44.9
PRODUCT MAXIMUM: 240 lb (109 kg)
VOLUME MAXIMUM: 150 quarts (190 liters)
**
.
ON WIRE SHELVES ONLY
ADDITIONAL WIRE SHELVES
REQUIRED FOR MAXIMUM CAPACITY
-
frEE
OPTION
kW
BREAKER
100
60

Advertisement