E L E C T R I C A L C O N N E C T I O N F O R g A S m O D E L S
1. An electrical wiring diagram is located behind
the control panel on the left side of the oven.
This appliance must be branch circuit protected
with proper ampacities, in accordance with the
wiring diagram.
DO NOT CONNECT TO A G.f.I. OUTLET.
2.
Random and/or nuisance breaker trips could
occur. Consult with the NEC codes for specific
load values.
3. Wire size for the main incoming power to the
unit must match the minimum size listed in the
specifications applicable to the specific oven
model. For supply connections, locate the wire
size posted on the label located on the electrical
control box cover, behind the service panel.
4. Before operating the oven, check all cable
connections and electrical terminal connections
in the electrical connection area for tightness
since connections can loosen during transport.
NOTICE: Check motor rotation on the
Combitherm® CT Classic CTC model
line. Arrows on the motor housing
indicate proper rotation.
After both water and electrical
connections have been completed on
all Combitherm model types, operate
the oven in any cooking mode for
a period of 15 minutes. Recheck
the main power connections at the
terminal block, cable connections, and
electrical terminal connections to make
certain they remain tight.
380-415V:
For CE approved units: To prevent an electrical
shock hazard between the appliance and other
appliances or metal parts in close vicinity,
an equalization-bonding stud is provided. An
equalization bonding lead must be connected to
this stud and the other appliances/metal parts
to provide sufficient protection against potential
difference. The terminal is marked with
the following symbol.
COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 39.
INSTALLATION
AV E RTI S SE m ENT
w A R N I N g
ELECTRICAL gROuNDINg
INSTRuCTIONS:
This appliance may be equipped with a
three-pronged (grounding) plug for your
protection against shock hazard and
should be plugged directly into a properly
grounded three-prong receptacle.
NEVER cut or remove the grounding
prong from this plug. Removing the
grounding prong may result in serious
injury, death or property damage.
Directives pour la prise de courant
électrique Cet appareil est muni d'une
fi che à trios branches (prise de Courant)
afi n de vous proéger des chocs et
doit être branché Directemet dans un
receptacle adequate de prise do courant
À trios branches. II ne faut pas couper
ou enlever une banche De cette fi che.

Advertisement