43-3/4"
(1111mm)
27-1/4"
(691mm)
41-7/8"
(1063mm)
WATER REQUIREMENTS
TWO (2) COLD WATER INLETS - DRINKING QUALITY
ONE (1) TREATED WATER INLET:
3/4" NPT*
ONE (1) UNTREATED WATER INLET: 3/4" NPT*
LINE PRESSURE: 30 psi minimum dynamic and 90 psi maximum static (2.1 to 6.3 bar)
WATER DRAIN: 1-1/2" (40mm)
CONNECTION WITH A
MATERIALS MUST WITHSTAND TEMPERATURES UP TO
CLEARANCE REQUIREMENTS
LEFT: 0" (0mm)
RIGHT: 0" (0mm)
NON-COMBUSTIBLE SURFACES
TOP: 20" (508mm)
FOR AIR MOVEMENT
4" (102mm)
BACK:
4-5/16" (109mm)
OPTIONAL PLUMBING KIT
INSTALLATION REQUIREMENTS
• Oven must be installed level.
• Water supply shut-off valve and back-flow preventer when required by local code.
ELECTRICAL - CTP20-20E
(NO CORD, NO PLUG, DEDICATED CIRCUIT REQUIRED) DO NOT CONNECT TO A G.F.I. OUTLET
VOLTAGE
PH
HZ
AWG
CONNECTION
208 – 240
3
50/60
4/0
L1, L2, L3, G
380 – 415
3
50/60 1 - 1/0 L1, L2, L3, N, G
440 – 480
3*
50/60 2 – 1
L1, L2, L3, G
*ELECTRICAL SERVICE CHARGE APPLIES
WEIGHT
SHIP DIMENSIONS
NET
1100 lbs est 499 kg
(L x W x H)
SHIP
1150 lbs*
522 kg*
(1346 x 1346 x 2210mm)*
*
.
DOMESTIC GROUND SHIPPING INFORMATION
CONTACT FACTORY FOR EXPORT
.
WEIGHT AND DIMENSIONS
COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 30.
47"
(1192mm)
B
A
D
1" (24mm)
33-9/16"
(852mm)
1-15/16" (49mm)
1-11/16" (42mm)
IP X5
* Can manifold off of
one 3/4" line
VERTICAL VENT TO EXTEND ABOVE THE EXHAUST VENT
200°F (93°C).
18" (457mm)
RECOMMENDED SERVICE ACCESS
2" (51mm)
DOOR SWING OR
COMBUSTIBLE SURFACES
BOTTOM: 5-1/8" (130mm)
FOR LEGS, AIR INTAKE
• Hood installation is required.
ECO
STANDARD
AMPS
kW
BREAKER
137.6 – 158.8 49.6 – 66 150 – 175 172 – 198.5 57.8 – 77 175 – 200 140.1 – 161.6 50.1 – 66.7 150 – 175 174.5 – 201.3 58.4 – 77.7 200 – 225
84.2 – 91.7
56.4 – 66
100
72.7 – 79.4
56.5 – 66
80
PAN CAPACITY
53" x 53" x 87"*
**FULL–SIZE SHEET:
A
C
3-1/4" (81mm)
4-3/16" (106mm)
5" (126mm)
7" (178mm)
DIMENSIONS: H x W x D
EXTERIOR:
79-1/4" x 43-3/4" x 47" (2012mm x 1111mm x 1192mm)
EXTERIOR WITH RECESSED DOOR:
79-1/4" x 48-3/4" x 47" (2012mm x 1238mm x 1192mm)
INTERIOR:
60-7/16" x 24-1/4" x 32-3/4" (1535mm x 616mm x 832mm)
WATER QUALITY STANDARDS
It is the sole responsibility of the owner/operator/purchaser of this equipment
to verify that the incoming water supply is comprehensively tested and if
required, a means of "water treatment" provided that would meet compliance
requirements with the published water quality standards shown below.
Non-compliance with these minimum standards will potentially damage this
.
equipment and/or components and void the original equipment manufacturer's
warranty. Alto-Shaam recommends using OptiPure
products to properly treat your water.
Total Dissolved Solids (tds)
**PROpower™
OPTION
AMPS
kW
BREAKER
AMPS
105.3 – 114.6 64.7 – 77
125
86.9 – 94.5 56.9 – 66.7
90.9 – 99.2
64.8 – 77
100
74.1 – 80.8 57.1 – 66.7 80 – 90
**NO-COST OPTION ON ELECTRIC MODELS
FULL–SIZE:
20" x 12" x 2-1/2"
GN 1/1:
530 x 325 x 65mm
GN 2/1:
650 x 530 x 65mm
Twenty (20)
18" x 26" x 1"
Twenty (20)
NOTES:
ALL DIMS LISTED AS H x W x D
CTP20-20E
INTERIOR DIMENSIONS: 1535mm X 616mm X 832mm
ElEctric boilEr
ElEctric boilEr
6-11/16" (168mm)
4-1/4" (108mm)
A, B, D
C - at bottom
of oven
B
D
47-7/8"
(1215mm)
A= UNTREATED WATER
B= TREATED WATER
C= ELECTRICAL
D= WATER DRAIN
®
[www.optipurewater.com]
Contaminant
Inlet Water Requirements
Free Chlorine
Less than 0.1 ppm (mg/L)
Hardness
30-70 ppm
Chloride
Less than 30 ppm (mg/L)
pH
7.0 to 8.5
Silica
Less than 12 ppm (mg/L)
50-125 ppm
®
WITH COMBISMOKER
OPTION
ECO
**PROpower™
STANDARD
kW
BREAKER
AMPS
100
107.9 – 117.5 65.3 – 77.7
92.3 – 100.7 65.4 – 77.7
PRODUCT MAXIMUM: 480 lb (218 kg)
Forty (40)
VOLUME MAXIMUM: 300 quarts (380 liters)
Forty (40)
**
.
ON WIRE SHELVES ONLY
REQUIRED FOR MAXIMUM CAPACITY
20.20es2
805606
20.20 ELECTRIC
-
frEE
OPTION
kW
BREAKER
150
100
ADDITIONAL WIRE SHELVES