Specifications, Ctp20-10G - COMBITHERM CT PROformance Series Installation Manual

Table of Contents

Advertisement

35-11/16" (906mm)
19-1/8" (486mm)
33-13/16" (858mm)
WATER REQUIREMENTS
TWO (2) COLD WATER INLETS - DRINKING QUALITY
ONE (1) TREATED WATER INLET:
3/4" NPT*
ONE (1) UNTREATED WATER INLET: 3/4" NPT*
LINE PRESSURE: 30 psi minimum dynamic and 90 psi maximum static (2.1 to 6.3 bar)
WATER DRAIN: 1-1/2" (40mm)
CONNECTION WITH A
MATERIALS MUST WITHSTAND TEMPERATURES UP TO
CLEARANCE REQUIREMENTS
LEFT: 0" (0mm)
RIGHT: 0" (0mm)
NON-COMBUSTIBLE SURFACES
TOP: 20" (508mm)
FOR AIR MOVEMENT
4" (102mm)
BACK:
4-5/16" (109mm)
OPTIONAL PLUMBING KIT
INSTALLATION REQUIREMENTS
• Oven must be installed level.
• Water supply shut-off valve and back-flow preventer when required by local code.
GAS REQUIREMENTS
(GAS TYPE MUST BE SPECIFIED ON ORDER)
RATED THERMAL LOAD
NORTH AMERICA
Natural Gas/Propane
Gross Heating Value (HHV)
Net Heating Value (LHV)
160,000 Btu / hr
ELECTRICAL - CTP20-10G
(DEDICATED CIRCUIT REQUIRED) DO NOT CONNECT TO A G.F.I. OUTLET
VOLTAGE
PH
HZ
120
1
60


208 – 240
50/60
1
¦


208 – 240
3
50/60

380 – 415
3
50/60

NORTH AMERICA VOLTAGE CHOICE

WEIGHT
SHIP DIMENSIONS
NET
905 lbs est 411 kg
(L x W x H)
SHIP
955 lbs*
433 kg*
(1422 x 1143 x 2210mm)*
*
.
DOMESTIC GROUND SHIPPING INFORMATION
CONTACT FACTORY FOR
.
EXPORT WEIGHT AND DIMENSIONS
COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 28.
NOTES:
ALL DIMS LISTED AS H x W x D
INTERIOR DIMENSIONS: 1535mm X 411mm X 712mm
EXTERIOR DIMENSIONS: 2012mm X 907mm X 995mm
42-1/4" (1072mm)
B
D
A
E
1" (24mm)
28-13/16" (732mm)
1-15/16" (49mm)
1-11/16" (42mm)
IP X5
* Can manifold off of
one 3/4" line
VERTICAL VENT TO EXTEND ABOVE THE EXHAUST VENT
200°F (93°C).
18" (457mm)
RECOMMENDED SERVICE ACCESS
2" (51mm)
DOOR SWING OR
COMBUSTIBLE SURFACES
BOTTOM: 5-1/8" (130mm)
FOR LEGS, AIR INTAKE
• Hood installation is required.
INTERNATIONAL
G20, G25, G31
Minimum: 5.5" W.C. dynamic
42.5 kW
Maximum: 14" W.C. static
CONNECTION
AWG
AMPS
no cord, no plug
14
L1, N, G
13.6
14
L1, L2/N, G
9.6 – 8.4
14
L1, L2, L3, G
9.6 – 8.4
14
L1, L2, L3, N, G
9.2 – 8.4
INTERNATIONAL VOLTAGE CHOICE

PAN CAPACITY
56" x 45" x 87"*
**HALF–SIZE SHEET:
20.10es2
805603
A, B, E
B
D
A
E
C
3-1/4" (81mm)
4-3/16" (106mm)
5" (126mm)
7" (178mm)
DIMENSIONS: H x W x D
EXTERIOR:
79-1/4" x 35-11/16" x 42-1/4" (2012mm x 906mm x 1072mm)
EXTERIOR WITH RECESSED DOOR:
79-1/4" x 40-11/16" x 42-1/4" (2012mm x 1033mm x 1072mm)
INTERIOR:
60-7/16" x 16-1/4" x 28-1/16" (1535mm x 411mm x 712mm)
WATER QUALITY STANDARDS
It is the sole responsibility of the owner/operator/purchaser of this equipment
to verify that the incoming water supply is comprehensively tested and if
required, a means of "water treatment" provided that would meet compliance
requirements with the published water quality standards shown below.
Non-compliance with these minimum standards will potentially damage this
.
equipment and/or components and void the original equipment manufacturer's
warranty. Alto-Shaam recommends using OptiPure
products to properly treat your water.
Total Dissolved Solids (tds)
HOOK-UP: 3/4" NPT
CONNECTED PRESSURE
NORTH AMERICA
Natural Gas
Minimum: 9" W.C. dynamic
Maximum: 14" W.C. static
CONNECTION
BREAKER
kW
no cord, no plug
20
1.7
L1, N, G
15
2.0
L1, L2/N, G
15
2.0
L1, L2, L3, G
15
2.0
L1, L2, L3, N, G
ELECTRICAL SERVICE CHARGE APPLIES
¦
FULL–SIZE:
20" x 12" x 2-1/2"
GN 1/1:
530 x 325 x 65mm
18" x 13" x 1"
20.10 GAS
CTP20-10G
Gas boilEr
6-11/16" (168mm)
4-1/4" (108mm)
C - at bottom
of oven
39-11/16" (1008mm)
A= UNTREATED WATER
B= TREATED WATER
C= ELECTRICAL
D= GAS
E= WATER DRAIN
®
[www.optipurewater.com]
Contaminant
Inlet Water Requirements
Free Chlorine
Less than 0.1 ppm (mg/L)
Hardness
30-70 ppm
Chloride
Less than 30 ppm (mg/L)
pH
7.0 to 8.5
Silica
Less than 12 ppm (mg/L)
50-125 ppm
INTERNATIONAL
Propane
G20 20mbar
G25 20mbar
G31 30mbar
WITH COMBISMOKER
OPTION
®
AMPS
BREAKER
15.8
20
12.1 – 11.3
15
12.1 – 11.3
15
11.8 – 11.3
15
PRODUCT MAXIMUM: 240 lb (109 kg)
Twenty (20)
VOLUME MAXIMUM: 150 quarts (190 liters)
Twenty (20)
Twenty (20)
**
ON WIRE SHELVES ONLY
REQUIRED FOR MAXIMUM CAPACITY
-
frEE
kW
2.32
2.5 – 2.7
2.5 – 2.7
2.6 – 2.7
.
ADDITIONAL WIRE SHELVES

Advertisement