PROBLEM
MACHINE FAILS TO
START WHEN
"WASHING PARTS"
PROCEDURE IS
FOLLOWED
TURNTABLE
DOES NOT
OPERATE
PROPERLY
PUMP DOES
NOT OPERATE
PROPERLY

OIL SKIMMER

DOES NOT
OPERATE
PROPERLY
POSSIBLE CAUSE
Main power disconnect is off
Lid/door is not closing
properly
Failed lid/door closure safety
switch
Failed washer cycle timer
Pump is not operating
properly
Parts are obstructing turntable
rotation
Drive chain is not on the drive
pulley
Turntable motor compression
springs are not installed
Blown fuse
Failed wash cycle timer
Low water level in sump
Pump intake is plugged
Pump overload relay is tripped
Blown fuse
Line voltage is too low
Pump is failed
Blown fuse
Cuda 2840 Operator's Manual 8.930-370.0 - AU
SOLUTION
Verify that no service is being performed on the
machine, then turn the main power disconnect on.
Check the lid/door closure safety switch; adjust
if necessary.
Test the lid/door closure safety switch; replace if
necessary (See Adjusting the Lid/Door Safety
Switch).
Test the wash cycle timer; replace if necessary (See
Lid/Door Safety Switch).
See Pump does not operate properly section.
Check for parts obstructing rotation of the
turntable; rearrange if necessary.
Check drive chain; realign on drive pulley
if necessary.
Check the turntable motor compression springs;
install if necessary (See Turntable Motor
Assembly).
Check electrical panel for blown fuse; replace
if necessary.
Test the electrical panel to eliminate the possibility of a
blown fuse then contact a licensed electrician or a
service representative to test the
turntable motor.
Check sump water level; add water if necessary.
Check pump intake for obstructions; clean out
if necessary.
Reset the motor overload relay.
Check electrical panel for a blown fuse; replace
if necessary.
Contact a licensed electrician to verify that the
line voltage matches unit voltage.
Test the electrical panel to eliminate the possibility of a
blown fuse then contact a licensed electrician or a
customer service representative to test the pump
motor.
Check electrical panel for a blown fuse;
replace if necessary.