Page 1
8.922 -402.0 For the Cuda Dealer nearest you, consult our web page at WARNING: www.CudaUSA.com This product can expose you to chemicals which are known to the State of California to cause cancer and birth defects or other reproductive harm.
KIT INSTRUCTIONS which came with the kit. It contains replacement parts numbers needed for ordering future parts. NOTE: The manual part number is located on the lower right corner of the front cover. CUDA 7248 Operator’s Manual 9.801-712.0 - Y...
When ordering parts, please specify model and serial number. Use only identical replacement parts. This machine is to be used only by trained operators. CUDA 7248 Operator’s Manual 9.801-712.0 - Y...
8. Use caution when lifting items in and out of parts pourraient survenir. basket to prevent back injuries. KEEP WATER SPRAY AWAY FROM 2.All installations must comply ELECTRICAL WIRING. with local codes. Contact your CUDA 7248 Operator’s Manual 9.801-712.0 - Y...
Page 7
16. After the machine stops, wait 10 seconds before opening the lid or door. This automatic parts washer is designed to operate safely and efficiently. Before you begin to install and use the machine, please familiarize yourself with the major components. CUDA 7248 Operator’s Manual 9.801-712.0 - Y...
Diss addi tank befo Fresh Water In Low Water Shut-Off Assy. Drive Motor Sump Cover Pivot Pump Heating Element & Thermostat Enclosure Compression Spring Assy. CUDA 7248 Operator’s Manual 9.801-712.0 - Y...
Step 3: Connect A Water Line This step is required for machines equipped with the optional automatic water fill system. If your machine does not have this option, skip this step. CUDA 7248 Operator’s Manual 9.801-712.0 - Y...
If you overfill the machine, remove excess water using a small submersible pump or a suitable container. The correct water level is two inches from the top of the sump tank when the pump is off. CUDA 7248 Operator’s Manual 9.801-712.0 - Y...
Increase/Decrease and unloading, you can rotate the turntable to easily Temperature add or remove parts. CUDA 7248 Operator’s Manual 9.801-712.0 - Y...
5. Tighten the adjustment nuts. 6. Replace the cover. When properly adjusted, you should hear a slight “click” as the door latch engages and compresses the door seal and the door closure safety switch. CUDA 7248 Operator’s Manual 9.801-712.0 - Y...
Brush the machine. Refer to for detailed installation informa- tion. To Air Power Brush Supply Throttle Lever Lock Position 2: Detail Holding Bracket Brush Throttle Lever To Air Outlet Supply To Detail Brush CUDA 7248 Operator’s Manual 9.801-712.0 - Y...
fl ow of cleaning solution through the detail brush. Air Flow Valve Flow Regulator WARNING: Hot, high-pressure cleaning solution could cause serious injury. Always wear rubber gloves and approved eye protection when handling hot cleaning solution. CUDA 7248 Operator’s Manual 9.801-712.0 - Y...
Top switch CLOSED, Bottom Switch Water Fill Valve (if installed) CLOSED, CLOSED, Automatic Water Fill Valve (if OPEN, Automatic Water Fill Valve (if Heating Element ON. installed) OPEN, Heating Element OFF. installed) OPEN, Heating Element OFF. CUDA 7248 Operator’s Manual 9.801-712.0 - Y...
AVERTISSEMENT: Utiliser la machine alors que le système de filtration est obstrué risquerait d'endo mager le sac du filtre. ARRÊTER IMMÉDIATEMENT LA MACHINE si la pression de sortie chute en deçà de 30 psi. CUDA 7248 Operator’s Manual 9.801-712.0 - Y...
• Clean the debris screen. • Set the wash cycle timer to OFF; • Set the heater timer to OFF; and • Shut off the compressed air at the supply line (if installed). CUDA 7248 Operator’s Manual 9.801-712.0 - Y...
NOTE: Spray degreaser and a damp cloth will usually remove all dirt and grime from the machine. For particularly stubborn soap deposits, use a soft cloth dampened with warm solution from the wash chamber. Door Spindle Grease Fittings CUDA 7248 Operator’s Manual 9.801-712.0 - Y...
To clean out the sump using the optional filtration and sump sweep system, perform the following procedure: CUDA 7248 Operator’s Manual 9.801-712.0 - Y...
Page 21
The use of any other 7. Add the appropriate amount of detergent and run detergent during the warranty period will void the the machine through a 30-minute wash cycle. Use warranty. CUDA 7248 Operator’s Manual 9.801-712.0 - Y...
When you install a new heating element, use are using a polyester felt filter bag, you must sealing tape or compound on the threads to deter replace it. Contact your distributor or call customer corrosion. CUDA 7248 Operator’s Manual 9.801-712.0 - Y...
2. Disengage the drive chain from the turntable. Secure Chain 3. Taking care not to kink or tangle the chain, place it 8. Disconnect all power leads from the motor, taking on the turntable. care to mark them for reassembly. CUDA 7248 Operator’s Manual 9.801-712.0 - Y...
• small flat-head screwdriver Replacement Procedure 1. Disconnect power to the machine. 2. Remove control panel face plate (four 5/16” screws). 3. Disconnect the wiring harness from the rear of the face plate. CUDA 7248 Operator’s Manual 9.801-712.0 - Y...
Page 25
Skimmer Motor 7. Reassemble the skimmer assembly and replace it on the machine. Assembly is the reverse of removal. Wire Nuts CUDA 7248 Operator’s Manual 9.801-712.0 - Y...
Electrical troubleshooting should be performed by qualified personnel only. • Avoid contact with power leads, terminals, and fuses when power is connected. • Disconnect power to machine before removing fuses or other electrical components. CUDA 7248 Operator’s Manual 9.801-712.0 - Y...
Page 27
Blown; Replace the Measure the Resistance of Each Blown Fuse approximately 0 Ohms E l e c t r i c a l Pa n e l i s OK. Refer to Testing Individual Components CUDA 7248 Operator’s Manual 9.801-712.0 - Y...
If there is continuity, the switch is no longer func- tional; replace the switch. 4. With the switch fully closed (depressed), test for continuity. If there is not continuity, the switch is no longer functional; replace the switch. CUDA 7248 Operator’s Manual 9.801-712.0 - Y...
(totally dissolved residue) more frequently. ON PARTS Large parts can dry before solution runs off, leaving powdery Turn heat down to approximately 140°. residue WASH SOLUTION Failed thermostat Replace the thermostat. TOO HOT CUDA 7248 Operator’s Manual 9.801-712.0 - Y...
Page 31
(See Detergent Concentration). RUSTING Leave door open if wash solution is cold and unit is Condensation collecting on door not in use. and inside of cabinet during long idle times. Add rust inhibitor solution. CUDA 7248 Operator’s Manual 9.801-712.0 - Y...
Page 32
Test the skimmer timer; replace if necessary Failed skimmer timer (See Wash Cycle, Heater and Skimmer Timers). Contact a licensed electrician to test the motor; Failed skimmer motors replace if necessary (See Oil Skimmer Motor). CUDA 7248 Operator’s Manual 9.801-712.0 - Y...
Cuda 7248 Front 26 62 For Detail See Door Latch Assy CUDA 7248 Operator’s Manual 9.801-712.0 - Y...
Page 35
ELBOW, 1/8" NPT 90° BLACK 8.916-280.0 NIPPLE, 1/8" X 3" LG SCH 40 BLACK 8.753-907.0 CHAIN, #35 X 631P 8.712-951.0 55" FOAM STRIP-1/8" X 1" ADHESIVE BACK 8.731-143.0 WASHER, 5/8" LOCKING 8.713-761.0 94" SEAL, BULB CUDA 7248 Operator’s Manual 9.801-712.0 - Y...
Page 36
NOT SHOWN 8.924-208.0 WLMT, PARTS TREE, 6 HOOK, APW NOT SHOWN 8.731-254.0 PARTS BASKET -SMALL 8 X 8 X 4 NOT SHOWN 8.924-172.0 BUCKET, OIL NOT SHOWN 8.925-463.0 BRACKET, APW FRONT LOAD GAP CUDA 7248 Operator’s Manual 9.801-712.0 - Y...
Page 37
Notes CUDA 7248 Operator’s Manual 9.801-712.0 - Y...
When sump your machi acture powde r’s recom • water, gent : Dissol cleani manuf NOTE before adding t to tank. amoun Assy CUDA 7248 Operator’s Manual 9.801-712.0 - Y...
Page 39
BOLT, 3/8" X 8" FULL THREAD 9.802-811.0 WASHER, 3/8" X 1-1/2" FENDER, SAE SPRING, COMPRESION 1.25" OD X 3" L X .148 9.25 8.749-423.0 COIL 9.802-817.0 WASHER, 3/8" 9.802-779.0 NUT, 3/8", ESNA, NC CUDA 7248 Operator’s Manual 9.801-712.0 - Y...
Spray Arm Side View View Rotate Each Nozzle Approx. 3° Align Notch In Each From Center Line Of Pipe Spray Nozzle With The Center Of The Turntabl CUDA 7248 Operator’s Manual 9.801-712.0 - Y...
Page 43
BUSHING, 1-1/2" X 1" NPT 8.753-729.0 CLAMP, T-BOLT 1-7/8" X 2-1/8" 8.749-190.0 31" HOSE, 1-1/2", 14 BAR 8.706-343.0 PIPE-BARBED/MALE 1-1/2" 8.706-328.0 PIPE PLUG 1/4, GALV 8.708-075.0 NOZZLE, 1 X 65 1/4' VEE JET SS CUDA 7248 Operator’s Manual 9.801-712.0 - Y...