6.5

Changing basic settings

In the basic settings menu it is possible to set the following parameters:
Parameter
Main frequency
Flow direction
Customer units
Q
max
Q
max
Totalizer
Low flow cut-off
Empty pipe cut-off
Velocity unit
Error level
Note
Totalizer 2 is not visible when batch is selected as digital output.
Note
Q
max
Change basic settings as follows:
1. Press top up key
2. Enter password.
3. Use forward key
4. Press lock/unlock key
5. Use forward key
6. Press lock/unlock key
7. Use select key
8. Press lock/unlock key
SITRANS F M MAG 5000/6000
Operating Instructions, 12/2013, A5E02338368-002
Description
Selection of main power supply frequency corresponding to the country in
which the flowmeter is installed (e.g. 60 Hz in America).
Selection of correct flow direction in pipe.
Setting of user defined volume and time units.
Setting of measuring range, analog outputs and frequency output. Also
individual dimension-dependent setting of value, decimal point, unit and time.
2
Setting of measuring range, analog outputs and frequency output. Also
individual dimension-dependent setting of value, decimal point, unit and time.
This menu is only visible if chosen as external digital input.
Setting of unit and decimal point.
Setting of a percentage of selected Q
reducing fluctuations in display and all outputs.
When set to "On" the alarm will indicate when sensor is running empty. All
readings, display and outputs, will indicate zero.
Setting of velocity unit per time unit
Selecting error level at which flowmeter will detect an error.
2 is visible only when chosen as digital input.
for 2 sec.
to reach basic settings menu.
or backward key
and change key
to unlock settings.
to reach relevant menu.
to unlock settings.
to change settings.
to confirm new settings.
6.5 Changing basic settings